dt-bindings: display: convert faraday,tve200 to YAML
Subsystems (3)
PATCH 1/1 dt-bindings: display: convert faraday,tve200 to YAML
Converts display/faraday,tve200.txt to yaml.
--- .../bindings/display/faraday,tve200.txt | 54 ----------- .../bindings/display/faraday,tve200.yaml | 92 +++++++++++++++++++ 2 files changed, 92 insertions(+), 54 deletions(-) delete mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.txt create mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.yaml
Documentation/devicetree/bindings/display/faraday,tve200.txt deleted +0 -54
@@ -1,54 +0,0 @@ -* Faraday TV Encoder TVE200 - -Required properties: - -- compatible: must be one of: - "faraday,tve200" - "cortina,gemini-tvc", "faraday,tve200" - -- reg: base address and size of the control registers block - -- interrupts: contains an interrupt specifier for the interrupt - line from the TVE200 - -- clock-names: should contain "PCLK" for the clock line clocking the - silicon and "TVE" for the 27MHz clock to the video driver - -- clocks: contains phandle and clock specifier pairs for the entries - in the clock-names property. See - Documentation/devicetree/bindings/clock/clock-bindings.txt - -Optional properties: - -- resets: contains the reset line phandle for the block - -Required sub-nodes: - -- port: describes LCD panel signals, following the common binding - for video transmitter interfaces; see - Documentation/devicetree/bindings/media/video-interfaces.txt - This port should have the properties: - reg = <0>; - It should have one endpoint connected to a remote endpoint where - the display is connected. - -Example: - -display-controller@6a000000 { - #address-cells = <1>; - #size-cells = <0>; - compatible = "faraday,tve200"; - reg = <0x6a000000 0x1000>; - interrupts = <13 IRQ_TYPE_EDGE_RISING>; - resets = <&syscon GEMINI_RESET_TVC>; - clocks = <&syscon GEMINI_CLK_GATE_TVC>, - <&syscon GEMINI_CLK_TVC>; - clock-names = "PCLK", "TVE"; - - port@0 { - reg = <0>; - display_out: endpoint { - remote-endpoint = <&panel_in>; - }; - }; -};
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +92 -0
92 lines not on this page · raw message
Signature · 1 line
2.26.3
Rob Herring
maintainerQuoted 87 lines · Corentin Labbe
Converts
display/faraday,tve200.txtto yaml.Signed-off-by Corentin Labbe <[email protected]>--- .../bindings/display/faraday,tve200.txt | 54 ----------- .../bindings/display/faraday,tve200.yaml | 92 +++++++++++++++++++ 2 files changed, 92 insertions(+), 54 deletions(-) delete mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.txt create mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.yamlDocumentation/devicetree/bindings/display/faraday,tve200.txt deleted +0
-54@@ -1,54 +0,0 @@ -* Faraday TV Encoder TVE200 - -Required properties: - -- compatible: must be one of: - "faraday,tve200" - "cortina,gemini-tvc", "faraday,tve200" - -- reg: base address and size of the control registers block - -- interrupts: contains an interrupt specifier for the interrupt - line from the TVE200 - -- clock-names: should contain "PCLK" for the clock line clocking the - silicon and "TVE" for the 27MHz clock to the video driver - -- clocks: contains phandle and clock specifier pairs for the entries - in the clock-names property. See - Documentation/devicetree/bindings/clock/clock-bindings.txt - -Optional properties: - -- resets: contains the reset line phandle for the block - -Required sub-nodes: - -- port: describes LCD panel signals, following the common binding - for video transmitter interfaces; see - Documentation/devicetree/bindings/media/video-interfaces.txt - This port should have the properties: - reg = <0>; - It should have one endpoint connected to a remote endpoint where - the display is connected. - -Example: - -display-controller@6a000000 { - #address-cells = <1>; - #size-cells = <0>; - compatible = "faraday,tve200"; - reg = <0x6a000000 0x1000>; - interrupts = <13 IRQ_TYPE_EDGE_RISING>; - resets = <&syscon GEMINI_RESET_TVC>; - clocks = <&syscon GEMINI_CLK_GATE_TVC>, - <&syscon GEMINI_CLK_TVC>; - clock-names = "PCLK", "TVE"; - - port@0 { - reg = <0>; - display_out: endpoint { - remote-endpoint = <&panel_in>; - }; - }; -};Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +11
-0@@ -0,0 +1,92 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/display/faraday,tve200.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Faraday TV Encoder TVE200 + +maintainers: + - Linus Walleij <[email protected]> +
Documentation/devicetree/bindings/display/faraday,tve200.yaml line 21
Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10
-0+properties: + compatible: + oneOf: + - const: faraday,tve200 + - items: + - const: cortina,gemini-tvc + - const: faraday,tve200 + + reg: + minItems: 1
maxItems: 1
They evaluate the same, but maxItems seems a bit more logical.
Quoted 13 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +13
-0+ + interrupts: + minItems: 1 + + clock-names: + items: + - const: PCLK + - const: TVE + + clocks: + minItems: 2 + + resets:
Documentation/devicetree/bindings/display/faraday,tve200.yaml line 44
Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10
-0+ minItems: 1 + + "#address-cells": + const: 1 + + "#size-cells": + const: 0 + +patternProperties: + "^port@[0-9]+$":
Should be just 'port' or 'port@0', but really the former is preferred when only 1.
Use the graph binding:
$ref: /schemas/graph.yaml#/properties/port
Documentation/devicetree/bindings/display/faraday,tve200.yaml line 46
Quoted 2 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +2
-0+ type: object + description: describes LCD panel signals, following the common binding
But this is not an LCD panel...
Documentation/devicetree/bindings/display/faraday,tve200.yaml line 48
Quoted 2 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +2
-0+ for video transmitter interfaces; see + Documentation/devicetree/bindings/media/video-interfaces.txt
Drop this reference. It's now a schema, but this isn't using anything from it.
Quoted 47 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +44
-0+ It should have one endpoint connected to a remote endpoint where + the display is connected. + + properties: + reg: + const: 0 + + required: + - reg + +required: + - compatible + - reg + - interrupts + - clock-names + - clocks + - "#address-cells" + - "#size-cells" + +additionalProperties: false + +examples: + - | + #include <dt-bindings/clock/cortina,gemini-clock.h> + #include <dt-bindings/interrupt-controller/irq.h> + #include <dt-bindings/reset/cortina,gemini-reset.h> + display-controller@6a000000 { + #address-cells = <1>; + #size-cells = <0>; + compatible = "faraday,tve200"; + reg = <0x6a000000 0x1000>; + interrupts = <13 IRQ_TYPE_EDGE_RISING>; + resets = <&syscon GEMINI_RESET_TVC>; + clocks = <&syscon GEMINI_CLK_GATE_TVC>, + <&syscon GEMINI_CLK_TVC>; + clock-names = "PCLK", "TVE"; + + port@0 { + reg = <0>; + display_out: endpoint { + remote-endpoint = <&panel_in>; + }; + }; + };Signature · 1 line
2.26.3
Quoted 130 lines · Rob Herring
Quoted 87 lines · Corentin Labbe
Converts
display/faraday,tve200.txtto yaml.Signed-off-by Corentin Labbe <[email protected]>--- .../bindings/display/faraday,tve200.txt | 54 ----------- .../bindings/display/faraday,tve200.yaml | 92 +++++++++++++++++++ 2 files changed, 92 insertions(+), 54 deletions(-) delete mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.txt create mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.yamlDocumentation/devicetree/bindings/display/faraday,tve200.txt deleted +0
-54@@ -1,54 +0,0 @@ -* Faraday TV Encoder TVE200 - -Required properties: - -- compatible: must be one of: - "faraday,tve200" - "cortina,gemini-tvc", "faraday,tve200" - -- reg: base address and size of the control registers block - -- interrupts: contains an interrupt specifier for the interrupt - line from the TVE200 - -- clock-names: should contain "PCLK" for the clock line clocking the - silicon and "TVE" for the 27MHz clock to the video driver - -- clocks: contains phandle and clock specifier pairs for the entries - in the clock-names property. See - Documentation/devicetree/bindings/clock/clock-bindings.txt - -Optional properties: - -- resets: contains the reset line phandle for the block - -Required sub-nodes: - -- port: describes LCD panel signals, following the common binding - for video transmitter interfaces; see - Documentation/devicetree/bindings/media/video-interfaces.txt - This port should have the properties: - reg = <0>; - It should have one endpoint connected to a remote endpoint where - the display is connected. - -Example: - -display-controller@6a000000 { - #address-cells = <1>; - #size-cells = <0>; - compatible = "faraday,tve200"; - reg = <0x6a000000 0x1000>; - interrupts = <13 IRQ_TYPE_EDGE_RISING>; - resets = <&syscon GEMINI_RESET_TVC>; - clocks = <&syscon GEMINI_CLK_GATE_TVC>, - <&syscon GEMINI_CLK_TVC>; - clock-names = "PCLK", "TVE"; - - port@0 { - reg = <0>; - display_out: endpoint { - remote-endpoint = <&panel_in>; - }; - }; -};Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +11
-0@@ -0,0 +1,92 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/display/faraday,tve200.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Faraday TV Encoder TVE200 + +maintainers: + - Linus Walleij <[email protected]> +Documentation/devicetree/bindings/display/faraday,tve200.yaml line 21
Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10
-0+properties: + compatible: + oneOf: + - const: faraday,tve200 + - items: + - const: cortina,gemini-tvc + - const: faraday,tve200 + + reg: + minItems: 1maxItems: 1
They evaluate the same, but maxItems seems a bit more logical.
Quoted 13 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +13
-0+ + interrupts: + minItems: 1 + + clock-names: + items: + - const: PCLK + - const: TVE + + clocks: + minItems: 2 + + resets:Documentation/devicetree/bindings/display/faraday,tve200.yaml line 44
Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10
-0+ minItems: 1 + + "#address-cells": + const: 1 + + "#size-cells": + const: 0 + +patternProperties: + "^port@[0-9]+$":Should be just 'port' or 'port@0', but really the former is preferred when only 1.
Quoted 4 lines
Use the graph binding:
$ref: /schemas/graph.yaml#/properties/port
I have a problem:
I get the following warning:
/usr/src/linux-next/arch/arm/boot/dts/gemini.dtsi:410.31-423.5: Warning (graph_child_address): /soc/display-controller@6a000000: graph node has single child node 'port@0', #address-cells/#size-cells are not necessary
also defined at /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:492.31-501.5
But if I remove them!
/usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:496.5-15: Warning (reg_format): /soc/display-controller@6a000000/port@0:reg: property has invalid length (4 bytes) (#address-cells == 2, #size-cells == 1) arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (pci_device_reg): Failed prerequisite 'reg_format'arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (pci_device_bus_num): Failed prerequisite 'reg_format'arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (simple_bus_reg): Failed prerequisite 'reg_format'arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (i2c_bus_reg): Failed prerequisite 'reg_format'arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (spi_bus_reg): Failed prerequisite 'reg_format'
/usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (avoid_default_addr_size): /soc/display-controller@6a000000/port@0: Relying on default #address-cells value /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (avoid_default_addr_size): /soc/display-controller@6a000000/port@0: Relying on default #size-cells value arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (avoid_unnecessary_addr_size): Failed prerequisite 'avoid_default_addr_size'arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (unique_unit_address): Failed prerequisite 'avoid_default_addr_size' /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (graph_port): /soc/display-controller@6a000000/port@0: graph node '#address-cells' is -1, must be 1 /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (graph_port): /soc/display-controller@6a000000/port@0: graph node '#size-cells' is -1, must be 0
The only solution is to remove "reg = <0>;" and calling the node "port". Does it is acceptable ?
Quoted 2 lines · LABBE Corentin
The only solution is to remove "reg = <0>;" and calling the node "port". Does it is acceptable ?
It's what I've done in the past at least so looks like the right thing to me. It is only used in this device tree:arch/arm/boot/dts/gemini-dlink-dir-685.dts
if you send me a patch to change port@0
to just port then I'll merge it pronto. (I can apply this patch to the DRM misc tree as well when Rob thing it's fine.)
Yours,
Linus Walleij