Skip to contentSkip to conversation

dt-bindings: display: convert faraday,tve200 to YAML

PATCH Superseded Corentin Labbe 3 participants 4 messages May 11, 2021 – May 18, 2021

Subsystems (3)

v1 of 2 Superseded Latest is v2 →

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 dt-bindings: display: convert faraday,tve200 to YAML

Converts display/faraday,tve200.txt to yaml.

---
 .../bindings/display/faraday,tve200.txt       | 54 -----------
 .../bindings/display/faraday,tve200.yaml      | 92 +++++++++++++++++++
 2 files changed, 92 insertions(+), 54 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.txt
 create mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.yaml
Documentation/devicetree/bindings/display/faraday,tve200.txt deleted +0 -54
deleted file mode 100644
index 82e3bc0b7485..000000000000
@@ -1,54 +0,0 @@
-* Faraday TV Encoder TVE200
-
-Required properties:
-
-- compatible: must be one of:
-	"faraday,tve200"
-	"cortina,gemini-tvc", "faraday,tve200"
-
-- reg: base address and size of the control registers block
-
-- interrupts: contains an interrupt specifier for the interrupt
-	line from the TVE200
-
-- clock-names: should contain "PCLK" for the clock line clocking the
-	silicon and "TVE" for the 27MHz clock to the video driver
-
-- clocks: contains phandle and clock specifier pairs for the entries
-	in the clock-names property. See
-	Documentation/devicetree/bindings/clock/clock-bindings.txt
-
-Optional properties:
-
-- resets: contains the reset line phandle for the block
-
-Required sub-nodes:
-
-- port: describes LCD panel signals, following the common binding
-	for video transmitter interfaces; see
-	Documentation/devicetree/bindings/media/video-interfaces.txt
-	This port should have the properties:
-	reg = <0>;
-	It should have one endpoint connected to a remote endpoint where
-	the display is connected.
-
-Example:
-
-display-controller@6a000000 {
-	#address-cells = <1>;
-	#size-cells = <0>;
-	compatible = "faraday,tve200";
-	reg = <0x6a000000 0x1000>;
-	interrupts = <13 IRQ_TYPE_EDGE_RISING>;
-	resets = <&syscon GEMINI_RESET_TVC>;
-	clocks = <&syscon GEMINI_CLK_GATE_TVC>,
-		 <&syscon GEMINI_CLK_TVC>;
-	clock-names = "PCLK", "TVE";
-
-	port@0 {
-		reg = <0>;
-		display_out: endpoint {
-			remote-endpoint = <&panel_in>;
-		};
-	};
-};
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +92 -0

92 lines not on this page · raw message

Signature · 1 line
2.26.3
maintainer
#1 lore raw
Quoted 87 lines · Corentin Labbe

Converts display/faraday,tve200.txt to yaml.

---
 .../bindings/display/faraday,tve200.txt       | 54 -----------
 .../bindings/display/faraday,tve200.yaml      | 92 +++++++++++++++++++
 2 files changed, 92 insertions(+), 54 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.txt
 create mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.yaml
Documentation/devicetree/bindings/display/faraday,tve200.txt deleted +0 -54
deleted file mode 100644
index 82e3bc0b7485..000000000000
@@ -1,54 +0,0 @@
-* Faraday TV Encoder TVE200
-
-Required properties:
-
-- compatible: must be one of:
-	"faraday,tve200"
-	"cortina,gemini-tvc", "faraday,tve200"
-
-- reg: base address and size of the control registers block
-
-- interrupts: contains an interrupt specifier for the interrupt
-	line from the TVE200
-
-- clock-names: should contain "PCLK" for the clock line clocking the
-	silicon and "TVE" for the 27MHz clock to the video driver
-
-- clocks: contains phandle and clock specifier pairs for the entries
-	in the clock-names property. See
-	Documentation/devicetree/bindings/clock/clock-bindings.txt
-
-Optional properties:
-
-- resets: contains the reset line phandle for the block
-
-Required sub-nodes:
-
-- port: describes LCD panel signals, following the common binding
-	for video transmitter interfaces; see
-	Documentation/devicetree/bindings/media/video-interfaces.txt
-	This port should have the properties:
-	reg = <0>;
-	It should have one endpoint connected to a remote endpoint where
-	the display is connected.
-
-Example:
-
-display-controller@6a000000 {
-	#address-cells = <1>;
-	#size-cells = <0>;
-	compatible = "faraday,tve200";
-	reg = <0x6a000000 0x1000>;
-	interrupts = <13 IRQ_TYPE_EDGE_RISING>;
-	resets = <&syscon GEMINI_RESET_TVC>;
-	clocks = <&syscon GEMINI_CLK_GATE_TVC>,
-		 <&syscon GEMINI_CLK_TVC>;
-	clock-names = "PCLK", "TVE";
-
-	port@0 {
-		reg = <0>;
-		display_out: endpoint {
-			remote-endpoint = <&panel_in>;
-		};
-	};
-};
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +11 -0
new file mode 100644
index 000000000000..3ab51e7e72af
@@ -0,0 +1,92 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/display/faraday,tve200.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Faraday TV Encoder TVE200
+
+maintainers:
+  - Linus Walleij <[email protected]>
+

Documentation/devicetree/bindings/display/faraday,tve200.yaml line 21

Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10 -0
+properties:
+  compatible:
+    oneOf:
+      - const: faraday,tve200
+      - items:
+          - const: cortina,gemini-tvc
+          - const: faraday,tve200
+
+  reg:
+    minItems: 1

maxItems: 1

They evaluate the same, but maxItems seems a bit more logical.

Quoted 13 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +13 -0
+
+  interrupts:
+    minItems: 1
+
+  clock-names:
+    items:
+      - const: PCLK
+      - const: TVE
+
+  clocks:
+    minItems: 2
+
+  resets:

Documentation/devicetree/bindings/display/faraday,tve200.yaml line 44

Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10 -0
+    minItems: 1
+
+  "#address-cells":
+    const: 1
+
+  "#size-cells":
+    const: 0
+
+patternProperties:
+  "^port@[0-9]+$":

Should be just 'port' or 'port@0', but really the former is preferred when only 1.

Use the graph binding:

$ref: /schemas/graph.yaml#/properties/port

Documentation/devicetree/bindings/display/faraday,tve200.yaml line 46

Quoted 2 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +2 -0
+    type: object
+    description: describes LCD panel signals, following the common binding

But this is not an LCD panel...

Documentation/devicetree/bindings/display/faraday,tve200.yaml line 48

Quoted 2 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +2 -0
+      for video transmitter interfaces; see
+      Documentation/devicetree/bindings/media/video-interfaces.txt

Drop this reference. It's now a schema, but this isn't using anything from it.

Quoted 47 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +44 -0
+      It should have one endpoint connected to a remote endpoint where
+      the display is connected.
+
+    properties:
+      reg:
+        const: 0
+
+    required:
+      - reg
+
+required:
+  - compatible
+  - reg
+  - interrupts
+  - clock-names
+  - clocks
+  - "#address-cells"
+  - "#size-cells"
+
+additionalProperties: false
+
+examples:
+  - |
+    #include <dt-bindings/clock/cortina,gemini-clock.h>
+    #include <dt-bindings/interrupt-controller/irq.h>
+    #include <dt-bindings/reset/cortina,gemini-reset.h>
+    display-controller@6a000000 {
+      #address-cells = <1>;
+      #size-cells = <0>;
+      compatible = "faraday,tve200";
+      reg = <0x6a000000 0x1000>;
+      interrupts = <13 IRQ_TYPE_EDGE_RISING>;
+      resets = <&syscon GEMINI_RESET_TVC>;
+      clocks = <&syscon GEMINI_CLK_GATE_TVC>,
+               <&syscon GEMINI_CLK_TVC>;
+      clock-names = "PCLK", "TVE";
+
+      port@0 {
+        reg = <0>;
+        display_out: endpoint {
+          remote-endpoint = <&panel_in>;
+        };
+      };
+    };
Signature · 1 line
2.26.3
#2 lore raw
Quoted 130 lines · Rob Herring
Quoted 87 lines · Corentin Labbe

Converts display/faraday,tve200.txt to yaml.

---
 .../bindings/display/faraday,tve200.txt       | 54 -----------
 .../bindings/display/faraday,tve200.yaml      | 92 +++++++++++++++++++
 2 files changed, 92 insertions(+), 54 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.txt
 create mode 100644 Documentation/devicetree/bindings/display/faraday,tve200.yaml
Documentation/devicetree/bindings/display/faraday,tve200.txt deleted +0 -54
deleted file mode 100644
index 82e3bc0b7485..000000000000
@@ -1,54 +0,0 @@
-* Faraday TV Encoder TVE200
-
-Required properties:
-
-- compatible: must be one of:
-	"faraday,tve200"
-	"cortina,gemini-tvc", "faraday,tve200"
-
-- reg: base address and size of the control registers block
-
-- interrupts: contains an interrupt specifier for the interrupt
-	line from the TVE200
-
-- clock-names: should contain "PCLK" for the clock line clocking the
-	silicon and "TVE" for the 27MHz clock to the video driver
-
-- clocks: contains phandle and clock specifier pairs for the entries
-	in the clock-names property. See
-	Documentation/devicetree/bindings/clock/clock-bindings.txt
-
-Optional properties:
-
-- resets: contains the reset line phandle for the block
-
-Required sub-nodes:
-
-- port: describes LCD panel signals, following the common binding
-	for video transmitter interfaces; see
-	Documentation/devicetree/bindings/media/video-interfaces.txt
-	This port should have the properties:
-	reg = <0>;
-	It should have one endpoint connected to a remote endpoint where
-	the display is connected.
-
-Example:
-
-display-controller@6a000000 {
-	#address-cells = <1>;
-	#size-cells = <0>;
-	compatible = "faraday,tve200";
-	reg = <0x6a000000 0x1000>;
-	interrupts = <13 IRQ_TYPE_EDGE_RISING>;
-	resets = <&syscon GEMINI_RESET_TVC>;
-	clocks = <&syscon GEMINI_CLK_GATE_TVC>,
-		 <&syscon GEMINI_CLK_TVC>;
-	clock-names = "PCLK", "TVE";
-
-	port@0 {
-		reg = <0>;
-		display_out: endpoint {
-			remote-endpoint = <&panel_in>;
-		};
-	};
-};
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +11 -0
new file mode 100644
index 000000000000..3ab51e7e72af
@@ -0,0 +1,92 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/display/faraday,tve200.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Faraday TV Encoder TVE200
+
+maintainers:
+  - Linus Walleij <[email protected]>
+

Documentation/devicetree/bindings/display/faraday,tve200.yaml line 21

Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10 -0
+properties:
+  compatible:
+    oneOf:
+      - const: faraday,tve200
+      - items:
+          - const: cortina,gemini-tvc
+          - const: faraday,tve200
+
+  reg:
+    minItems: 1

maxItems: 1

They evaluate the same, but maxItems seems a bit more logical.

Quoted 13 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +13 -0
+
+  interrupts:
+    minItems: 1
+
+  clock-names:
+    items:
+      - const: PCLK
+      - const: TVE
+
+  clocks:
+    minItems: 2
+
+  resets:

Documentation/devicetree/bindings/display/faraday,tve200.yaml line 44

Quoted 10 lines
Documentation/devicetree/bindings/display/faraday,tve200.yaml new file +10 -0
+    minItems: 1
+
+  "#address-cells":
+    const: 1
+
+  "#size-cells":
+    const: 0
+
+patternProperties:
+  "^port@[0-9]+$":

Should be just 'port' or 'port@0', but really the former is preferred when only 1.

Quoted 4 lines

Use the graph binding:

$ref: /schemas/graph.yaml#/properties/port

I have a problem:

I get the following warning:
/usr/src/linux-next/arch/arm/boot/dts/gemini.dtsi:410.31-423.5: Warning (graph_child_address): /soc/display-controller@6a000000: graph node has single child node 'port@0', #address-cells/#size-cells are not necessary
also defined at /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:492.31-501.5

But if I remove them!
/usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:496.5-15: Warning (reg_format): /soc/display-controller@6a000000/port@0:reg: property has invalid length (4 bytes) (#address-cells == 2, #size-cells == 1) arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (pci_device_reg): Failed prerequisite 'reg_format'
arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (pci_device_bus_num): Failed prerequisite 'reg_format'
arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (simple_bus_reg): Failed prerequisite 'reg_format'
arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (i2c_bus_reg): Failed prerequisite 'reg_format'
arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (spi_bus_reg): Failed prerequisite 'reg_format'
/usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (avoid_default_addr_size): /soc/display-controller@6a000000/port@0: Relying on default #address-cells value /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (avoid_default_addr_size): /soc/display-controller@6a000000/port@0: Relying on default #size-cells value arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (avoid_unnecessary_addr_size): Failed prerequisite 'avoid_default_addr_size'
arch/arm/boot/dts/gemini-dlink-dir-685.dt.yaml: Warning (unique_unit_address): Failed prerequisite 'avoid_default_addr_size' /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (graph_port): /soc/display-controller@6a000000/port@0: graph node '#address-cells' is -1, must be 1 /usr/src/linux-next/arch/arm/boot/dts/gemini-dlink-dir-685.dts:495.11-500.6: Warning (graph_port): /soc/display-controller@6a000000/port@0: graph node '#size-cells' is -1, must be 0

The only solution is to remove "reg = <0>;" and calling the node "port". Does it is acceptable ?

#3 lore raw
Quoted 2 lines · LABBE Corentin

The only solution is to remove "reg = <0>;" and calling the node "port". Does it is acceptable ?

It's what I've done in the past at least so looks like the right thing to me. It is only used in this device tree:
arch/arm/boot/dts/gemini-dlink-dir-685.dts
if you send me a patch to change port@0
to just port then I'll merge it pronto. (I can apply this patch to the DRM misc tree as well when Rob thing it's fine.)

Yours,
Linus Walleij