virtiofsd: Find original inode ID of mount points
cover virtiofsd: Find original inode ID of mount points
Hi,
Not announcing submounts to the guest may lead to duplicated st_dev/st_ino combinations, because inodes on different filesystems (different st_dev) may share the same inode ID (st_ino). If the guest only sees a single st_dev, those inodes will appear to have the same st_dev/st_ino combination.
Announcing submounts is supposed to solve this problem by making the guest report different st_dev IDs for different filesystems.
However, there is one loop hole: Submounts are implemented as auto-mounts, meaning when the virtio-fs filesystem is mounted, the submounts will not be mounted immediately. In the guest, it is possible to stat() these mount points with AT_NO_AUTOMOUNT to receive information without mounting them, so they will then show whatever st_ino virtiofsd passes, and the st_dev of the parent filesystem.
Unfortunately, as far as we understood, the only st_ino that virtiofsd could inquire was the one on the submounted filesystem, i.e. the st_ino of that FS’s root node.
Thus, we again got a collision: In said case, the guest would see st_dev of the parent FS, but st_ino of the submounted FS. This is very likely to be the same st_dev/st_ino combination as the root node of the parent FS.
For nested mount structures, this can be reproduced with find:
Mounting several filesystems under each other, passing everything into a guest, mounting the root virtio-fs FS there, and then invoking find would likely result in it complaining about filesystem loops and refusing to visit the submount points. (These loops are reported because it takes notes of st_dev/st_ino combinations, and then reports a loop when some combination reappears.) This can only be fixed by forcing all submounts to be (auto-)mounted.
What we’d need to do is report the inode ID of the mount point directory that it has on the parent filesystem to the guest, until the submount is auto-mounted there. It’s just that we thought there was no way to inquire this parent FS st_ino.
It turns out that our understand was wrong, though: There is a way, namely readdir(). The dirent.d_ino field represents (in practice) the st_ino of some directory entry on the directory’s filesystem, and so is exactly the value we want to give to the guest.
Let’s do that.
Max Reitz (3):
virtiofsd: Find original inode ID of mount points virtiofs_submounts.py: Do not generate ssh key virtiofs_submounts.py: Check find
tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++- tests/acceptance/virtiofs_submounts.py | 10 +- .../virtiofs_submounts.py.data/guest.sh | 56 ++++------ 3 files changed, 122 insertions(+), 48 deletions(-)
Signature · 1 line
2.31.1
PATCH 1/3 virtiofsd: Find original inode ID of mount points
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.
There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr and that stat(2) call will return the inode ID for the submount.)
--- tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++-- 1 file changed, 99 insertions(+), 5 deletions(-)
tools/virtiofsd/passthrough_ll.c +99 -5
@@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,return 0 ; } +/* +* Use readdir() to find mp_name's inode ID on the parent's filesystem. +* (For mount points, stat() will only return the inode ID on the +* filesystem mounted there, i.e. the root directory's inode ID. The +* mount point originally was a directory on the parent filesystem, +* though, and so has a different inode ID there. When passing +* submount information to the guest, we need to pass this other ID, +* so the guest can use it as the inode ID until the submount is +* auto-mounted. (At which point the guest will invoke getattr and +* find the inode ID on the submount.)) +* +* Return 0 on success, and -errno otherwise. *pino is set only in +* case of success. +*/ +static int get_mp_ino_on_parent (const struct lo_inode *dir,const char *mp_name, +ino_t *pino) +{ +int dirfd =-1 ; +int ret; +DIR *dp =NULL ; + + dirfd =openat (dir->fd,"." ,O_RDONLY ); +if (dirfd <0 ) { + ret = -errno; + goto out; + } + + dp =fdopendir (dirfd); +if (!dp) { + ret = -errno; + goto out; + } +/* Owned by dp now */ + dirfd =-1 ; + +while (true) { +struct dirent *de; + + errno =0 ; + de =readdir (dp); +if (!de) { + ret = errno ? -errno : -ENOENT ; + goto out; + } + +if (!strcmp (de->d_name, mp_name)) { + *pino = de->d_ino; + ret =0 ; + goto out; + } + } + +out: +if (dp) { +closedir (dp); + } +if (dirfd >=0 ) { +close (dirfd); + } +return ret; +} +/* * Increments nlookup on the inode on success. unref_inode_lolocked() must be * called eventually to decrement nlookup again. If inodep is non-NULL, the * inode pointer is stored and the caller must call lo_inode_put(). +* +* If parent_fs_st_ino is true, the entry is a mount point, and submounts are +* announced to the guest, set e->attr.st_ino to the entry's inode ID on its +* parent filesystem instead of its inode ID on the filesystem mounted on it. +* (For mount points, the entry encompasses two inodes: One on the parent FS, +* and one on the mounted FS (where it is the root node), so it has two inode +* IDs. When looking up entries, we should show the guest the parent FS's inode +* ID, because as long as the guest has not auto-mounted the submount, it should +* see that original ID. Once it does perform the auto-mount, it will invoke +* getattr and see the root node's inode ID.) */ static int lo_do_lookup (fuse_req_t req,fuse_ino_t parent,const char *name,struct fuse_entry_param *e, -struct lo_inode **inodep) +struct lo_inode **inodep, +bool parent_fs_st_ino) {int newfd;int res;
@@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,struct lo_data *lo =lo_data (req);struct lo_inode *inode =NULL ;struct lo_inode *dir =lo_inode (req, parent); +ino_t ino_id_for_guest;if (inodep) { *inodep =NULL ;/* in case there is an error */
@@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, goto out_err; } + ino_id_for_guest = e->attr.st_ino; +if (S_ISDIR (e->attr.st_mode) && lo->announce_submounts && (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) { e->attr_flags |=FUSE_ATTR_SUBMOUNT ; + +if (parent_fs_st_ino) { +/* +* Best effort, so ignore errors. +* Also note that using readdir() means there may be races: +* The directory entry we find (if any) may be different +* from newfd. Again, this is a best effort. Reporting +* the wrong inode ID to the guest is not catastrophic. +*/ +get_mp_ino_on_parent (dir, name, &ino_id_for_guest); + } } inode =lo_find (lo, &e->attr, mnt_id);
@@ -1043,6 +1130,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, inode->nlookup =1 ; inode->fd = newfd; +/* +* For the inode key, use the dev/ino/mnt ID as reported by stat() +* (i.e. not ino_id_for_guest) +*/ inode->key.ino = e->attr.st_ino; inode->key.dev = e->attr.st_dev; inode->key.mnt_id = mnt_id;
@@ -1058,6 +1149,9 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, } e->ino = inode->fuse_ino; +/* Report ino_id_for_guest to the guest */ + e->attr.st_ino = ino_id_for_guest; +/* Transfer ownership of inode pointer to caller or drop it */ if (inodep) { *inodep = inode;
@@ -1104,7 +1198,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)return ; } - err =lo_do_lookup (req, parent, name, &e,NULL ); + err =lo_do_lookup (req, parent, name, &e,NULL , true);if (err) {fuse_reply_err (req, err); }else {
@@ -1217,7 +1311,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent, goto out; } - saverr =lo_do_lookup (req, parent, name, &e,NULL ); + saverr =lo_do_lookup (req, parent, name, &e,NULL , false);if (saverr) { goto out; }
@@ -1714,7 +1808,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,if (plus) {if (!is_dot_or_dotdot (name)) { - err =lo_do_lookup (req, ino, name, &e,NULL ); + err =lo_do_lookup (req, ino, name, &e,NULL , true);if (err) { goto error; }
@@ -1936,7 +2030,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name, goto out; } - err =lo_do_lookup (req, parent, name, &e, &inode); + err =lo_do_lookup (req, parent, name, &e, &inode, false);if (err) { goto out; }
Signature · 1 line
2.31.1
Quoted 30 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the
root node of the filesystem mounted there. Thus, they have two inode IDs.Right now, we only report the latter inode ID (i.e. the inode ID of the
mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount,
they have the device ID of the parent and the inode ID for the submount.
This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example withfind, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.There is a way to find the mount directory's original inode ID, and that
is to readdir(3) the parent directory, look for the mount directory, and
read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr
and that stat(2) call will return the inode ID for the submount.)
Quoted 2 lines
Signed-off-by Max Reitz <[email protected]>---
This is a clever way of uncovering the inode ID.
Quoted 138 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr and that stat(2) call will return the inode ID for the submount.)
Signed-off-by Max Reitz <[email protected]>--- tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++-- 1 file changed, 99 insertions(+), 5 deletions(-)tools/virtiofsd/passthrough_ll.c +77
-1@@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,return 0 ; } +/* +* Use readdir() to find mp_name's inode ID on the parent's filesystem. +* (For mount points, stat() will only return the inode ID on the +* filesystem mounted there, i.e. the root directory's inode ID. The +* mount point originally was a directory on the parent filesystem, +* though, and so has a different inode ID there. When passing +* submount information to the guest, we need to pass this other ID, +* so the guest can use it as the inode ID until the submount is +* auto-mounted. (At which point the guest will invoke getattr and +* find the inode ID on the submount.)) +* +* Return 0 on success, and -errno otherwise. *pino is set only in +* case of success. +*/ +static int get_mp_ino_on_parent (const struct lo_inode *dir,const char *mp_name, +ino_t *pino) +{ +int dirfd =-1 ; +int ret; +DIR *dp =NULL ; + + dirfd =openat (dir->fd,"." ,O_RDONLY ); +if (dirfd <0 ) { + ret = -errno; + goto out; + } + + dp =fdopendir (dirfd); +if (!dp) { + ret = -errno; + goto out; + } +/* Owned by dp now */ + dirfd =-1 ; + +while (true) { +struct dirent *de; + + errno =0 ; + de =readdir (dp); +if (!de) { + ret = errno ? -errno : -ENOENT ; + goto out; + } + +if (!strcmp (de->d_name, mp_name)) { + *pino = de->d_ino; + ret =0 ; + goto out; + } + } + +out: +if (dp) { +closedir (dp); + } +if (dirfd >=0 ) { +close (dirfd); + } +return ret; +} +/* * Increments nlookup on the inode on success. unref_inode_lolocked() must be * called eventually to decrement nlookup again. If inodep is non-NULL, the * inode pointer is stored and the caller must call lo_inode_put(). +* +* If parent_fs_st_ino is true, the entry is a mount point, and submounts are +* announced to the guest, set e->attr.st_ino to the entry's inode ID on its +* parent filesystem instead of its inode ID on the filesystem mounted on it. +* (For mount points, the entry encompasses two inodes: One on the parent FS, +* and one on the mounted FS (where it is the root node), so it has two inode +* IDs. When looking up entries, we should show the guest the parent FS's inode +* ID, because as long as the guest has not auto-mounted the submount, it should +* see that original ID. Once it does perform the auto-mount, it will invoke +* getattr and see the root node's inode ID.) */ static int lo_do_lookup (fuse_req_t req,fuse_ino_t parent,const char *name,struct fuse_entry_param *e, -struct lo_inode **inodep) +struct lo_inode **inodep, +bool parent_fs_st_ino) {int newfd;int res;@@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,struct lo_data *lo =lo_data (req);struct lo_inode *inode =NULL ;struct lo_inode *dir =lo_inode (req, parent); +ino_t ino_id_for_guest;if (inodep) { *inodep =NULL ;/* in case there is an error */ @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, goto out_err; } + ino_id_for_guest = e->attr.st_ino; +if (S_ISDIR (e->attr.st_mode) && lo->announce_submounts && (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) { e->attr_flags |=FUSE_ATTR_SUBMOUNT ;
tools/virtiofsd/passthrough_ll.c static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, · line 1109
Quoted 10 lines
tools/virtiofsd/passthrough_ll.c +10
-0+ +if (parent_fs_st_ino) { +/* +* Best effort, so ignore errors. +* Also note that using readdir() means there may be races: +* The directory entry we find (if any) may be different +* from newfd. Again, this is a best effort. Reporting +* the wrong inode ID to the guest is not catastrophic. +*/ +get_mp_ino_on_parent (dir, name, &ino_id_for_guest);
Hi Max,
[CC virtio-fs list ]
In general patch looks good to me. A minor nit. get_mp_ino_on_parent() is retruning error. It might be better to capture error and print a message and continue.
I have couple of general questions about submounts.
- What happens in case of single file mounted on top of another file.
mount --bind foo.txt bar.txt
Do submounts work when mount point is not a directory.
- Say a directory is not a mount point yet and lookup instantiates an inode. Later user mounts something on that directory. When does client/server notice this change. I am assuming this is probably part of revalidation path.
Thanks
Vivek
Quoted 65 lines
tools/virtiofsd/passthrough_ll.c +12
-4+ } } inode =lo_find (lo, &e->attr, mnt_id);@@ -1043,6 +1130,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, inode->nlookup =1 ; inode->fd = newfd; +/* +* For the inode key, use the dev/ino/mnt ID as reported by stat() +* (i.e. not ino_id_for_guest) +*/ inode->key.ino = e->attr.st_ino; inode->key.dev = e->attr.st_dev; inode->key.mnt_id = mnt_id;@@ -1058,6 +1149,9 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, } e->ino = inode->fuse_ino; +/* Report ino_id_for_guest to the guest */ + e->attr.st_ino = ino_id_for_guest; +/* Transfer ownership of inode pointer to caller or drop it */ if (inodep) { *inodep = inode;@@ -1104,7 +1198,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)return ; } - err =lo_do_lookup (req, parent, name, &e,NULL ); + err =lo_do_lookup (req, parent, name, &e,NULL , true);if (err) {fuse_reply_err (req, err); }else {@@ -1217,7 +1311,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent, goto out; } - saverr =lo_do_lookup (req, parent, name, &e,NULL ); + saverr =lo_do_lookup (req, parent, name, &e,NULL , false);if (saverr) { goto out; }@@ -1714,7 +1808,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,if (plus) {if (!is_dot_or_dotdot (name)) { - err =lo_do_lookup (req, ino, name, &e,NULL ); + err =lo_do_lookup (req, ino, name, &e,NULL , true);if (err) { goto error; }@@ -1936,7 +2030,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name, goto out; } - err =lo_do_lookup (req, parent, name, &e, &inode); + err =lo_do_lookup (req, parent, name, &e, &inode, false);if (err) { goto out; }Signature · 1 line
2.31.1
Quoted 152 lines · Vivek Goyal
Quoted 138 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr and that stat(2) call will return the inode ID for the submount.)
Signed-off-by Max Reitz <[email protected]>--- tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++-- 1 file changed, 99 insertions(+), 5 deletions(-)tools/virtiofsd/passthrough_ll.c +77
-1@@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,return 0 ; } +/* +* Use readdir() to find mp_name's inode ID on the parent's filesystem. +* (For mount points, stat() will only return the inode ID on the +* filesystem mounted there, i.e. the root directory's inode ID. The +* mount point originally was a directory on the parent filesystem, +* though, and so has a different inode ID there. When passing +* submount information to the guest, we need to pass this other ID, +* so the guest can use it as the inode ID until the submount is +* auto-mounted. (At which point the guest will invoke getattr and +* find the inode ID on the submount.)) +* +* Return 0 on success, and -errno otherwise. *pino is set only in +* case of success. +*/ +static int get_mp_ino_on_parent (const struct lo_inode *dir,const char *mp_name, +ino_t *pino) +{ +int dirfd =-1 ; +int ret; +DIR *dp =NULL ; + + dirfd =openat (dir->fd,"." ,O_RDONLY ); +if (dirfd <0 ) { + ret = -errno; + goto out; + } + + dp =fdopendir (dirfd); +if (!dp) { + ret = -errno; + goto out; + } +/* Owned by dp now */ + dirfd =-1 ; + +while (true) { +struct dirent *de; + + errno =0 ; + de =readdir (dp); +if (!de) { + ret = errno ? -errno : -ENOENT ; + goto out; + } + +if (!strcmp (de->d_name, mp_name)) { + *pino = de->d_ino; + ret =0 ; + goto out; + } + } + +out: +if (dp) { +closedir (dp); + } +if (dirfd >=0 ) { +close (dirfd); + } +return ret; +} +/* * Increments nlookup on the inode on success. unref_inode_lolocked() must be * called eventually to decrement nlookup again. If inodep is non-NULL, the * inode pointer is stored and the caller must call lo_inode_put(). +* +* If parent_fs_st_ino is true, the entry is a mount point, and submounts are +* announced to the guest, set e->attr.st_ino to the entry's inode ID on its +* parent filesystem instead of its inode ID on the filesystem mounted on it. +* (For mount points, the entry encompasses two inodes: One on the parent FS, +* and one on the mounted FS (where it is the root node), so it has two inode +* IDs. When looking up entries, we should show the guest the parent FS's inode +* ID, because as long as the guest has not auto-mounted the submount, it should +* see that original ID. Once it does perform the auto-mount, it will invoke +* getattr and see the root node's inode ID.) */ static int lo_do_lookup (fuse_req_t req,fuse_ino_t parent,const char *name,struct fuse_entry_param *e, -struct lo_inode **inodep) +struct lo_inode **inodep, +bool parent_fs_st_ino) {int newfd;int res;@@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,struct lo_data *lo =lo_data (req);struct lo_inode *inode =NULL ;struct lo_inode *dir =lo_inode (req, parent); +ino_t ino_id_for_guest;if (inodep) { *inodep =NULL ;/* in case there is an error */ @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, goto out_err; } + ino_id_for_guest = e->attr.st_ino; +if (S_ISDIR (e->attr.st_mode) && lo->announce_submounts && (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) { e->attr_flags |=FUSE_ATTR_SUBMOUNT ;tools/virtiofsd/passthrough_ll.c static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, · line 1109
Quoted 10 lines
tools/virtiofsd/passthrough_ll.c +10
-0+ +if (parent_fs_st_ino) { +/* +* Best effort, so ignore errors. +* Also note that using readdir() means there may be races: +* The directory entry we find (if any) may be different +* from newfd. Again, this is a best effort. Reporting +* the wrong inode ID to the guest is not catastrophic. +*/ +get_mp_ino_on_parent (dir, name, &ino_id_for_guest);Hi Max,
Quoted 5 lines
[CC virtio-fs list ]
In general patch looks good to me. A minor nit.
get_mp_ino_on_parent()is retruning error. It might be better to capture error and print a message and continue.
Sure, why not.
Quoted 7 lines
I have couple of general questions about submounts.
- What happens in case of single file mounted on top of another file.
mount --bind foo.txt bar.txtDo submounts work when mount point is not a directory.
No, as you can see in the condition quoted above, we only set the FUSE_ATTR_SUBMOUNT flag for directories. That seemed the most common case for me, and I didn’t want to have to worry about weirdness that might ensue for file mounts.
Quoted 4 lines
- Say a directory is not a mount point yet and lookup instantiates an inode. Later user mounts something on that directory. When does client/server notice this change. I am assuming this is probably part of revalidation path.
I guess at least before this patch this is no different from any other filesystem change. Because st_dev+st_ino changed, it should basically look like the old directory was removed and a different one was put in its place.
Now, with this patch, we will return the old st_ino to the guest, but internally virtiofsd will still use the submount’s st_dev/st_ino, so a new lo_inode should be created, and so fuse_dentry_revalidate()’s lookup should return a different node ID, resulting it to consider the entry expired.
Besides, fuse_dentry_revalidate() has a condition on IS_AUTOMOUNT(inode) != flags & FUSE_ATTR_SUBMOUNT. Considering the previous paragraph, this doesn’t seem necessary to me, but it can’t hurt.
Max
Quoted 162 lines · * Max Reitz ([email protected]) wrote:
Quoted 149 lines · Vivek Goyal
Quoted 135 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr and that stat(2) call will return the inode ID for the submount.)
Signed-off-by Max Reitz <[email protected]>--- tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++-- 1 file changed, 99 insertions(+), 5 deletions(-)tools/virtiofsd/passthrough_ll.c +77
-1@@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,return 0 ; } +/* +* Use readdir() to find mp_name's inode ID on the parent's filesystem. +* (For mount points, stat() will only return the inode ID on the +* filesystem mounted there, i.e. the root directory's inode ID. The +* mount point originally was a directory on the parent filesystem, +* though, and so has a different inode ID there. When passing +* submount information to the guest, we need to pass this other ID, +* so the guest can use it as the inode ID until the submount is +* auto-mounted. (At which point the guest will invoke getattr and +* find the inode ID on the submount.)) +* +* Return 0 on success, and -errno otherwise. *pino is set only in +* case of success. +*/ +static int get_mp_ino_on_parent (const struct lo_inode *dir,const char *mp_name, +ino_t *pino) +{ +int dirfd =-1 ; +int ret; +DIR *dp =NULL ; + + dirfd =openat (dir->fd,"." ,O_RDONLY ); +if (dirfd <0 ) { + ret = -errno; + goto out; + } + + dp =fdopendir (dirfd); +if (!dp) { + ret = -errno; + goto out; + } +/* Owned by dp now */ + dirfd =-1 ; + +while (true) { +struct dirent *de; + + errno =0 ; + de =readdir (dp); +if (!de) { + ret = errno ? -errno : -ENOENT ; + goto out; + } + +if (!strcmp (de->d_name, mp_name)) { + *pino = de->d_ino; + ret =0 ; + goto out; + } + } + +out: +if (dp) { +closedir (dp); + } +if (dirfd >=0 ) { +close (dirfd); + } +return ret; +} +/* * Increments nlookup on the inode on success. unref_inode_lolocked() must be * called eventually to decrement nlookup again. If inodep is non-NULL, the * inode pointer is stored and the caller must call lo_inode_put(). +* +* If parent_fs_st_ino is true, the entry is a mount point, and submounts are +* announced to the guest, set e->attr.st_ino to the entry's inode ID on its +* parent filesystem instead of its inode ID on the filesystem mounted on it. +* (For mount points, the entry encompasses two inodes: One on the parent FS, +* and one on the mounted FS (where it is the root node), so it has two inode +* IDs. When looking up entries, we should show the guest the parent FS's inode +* ID, because as long as the guest has not auto-mounted the submount, it should +* see that original ID. Once it does perform the auto-mount, it will invoke +* getattr and see the root node's inode ID.) */ static int lo_do_lookup (fuse_req_t req,fuse_ino_t parent,const char *name,struct fuse_entry_param *e, -struct lo_inode **inodep) +struct lo_inode **inodep, +bool parent_fs_st_ino) {int newfd;int res;@@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,struct lo_data *lo =lo_data (req);struct lo_inode *inode =NULL ;struct lo_inode *dir =lo_inode (req, parent); +ino_t ino_id_for_guest;if (inodep) { *inodep =NULL ;/* in case there is an error */ @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, goto out_err; } + ino_id_for_guest = e->attr.st_ino; +if (S_ISDIR (e->attr.st_mode) && lo->announce_submounts && (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) { e->attr_flags |=FUSE_ATTR_SUBMOUNT ;tools/virtiofsd/passthrough_ll.c static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, · line 1108
Quoted 10 lines
tools/virtiofsd/passthrough_ll.c +10
-0+ +if (parent_fs_st_ino) { +/* +* Best effort, so ignore errors. +* Also note that using readdir() means there may be races: +* The directory entry we find (if any) may be different +* from newfd. Again, this is a best effort. Reporting +* the wrong inode ID to the guest is not catastrophic. +*/ +get_mp_ino_on_parent (dir, name, &ino_id_for_guest);Hi Max,
Quoted 5 lines
[CC virtio-fs list ]
In general patch looks good to me. A minor nit.
get_mp_ino_on_parent()is retruning error. It might be better to capture error and print a message and continue.Sure, why not.
Quoted 4 lines
I have couple of general questions about submounts.
- What happens in case of single file mounted on top of another file.
Quoted 8 lines
Quoted 3 lines
mount --bind foo.txt bar.txtDo submounts work when mount point is not a directory.
No, as you can see in the condition quoted above, we only set the
FUSE_ATTR_SUBMOUNTflag for directories. That seemed the most common case for me, and I didn’t want to have to worry about weirdness that might ensue for file mounts.
It might be worth checking file mounts don't break too badly; I'm pretty sure I've seen the container systems use them a lot in /etc
Dave
Quoted 19 lines
Quoted 4 lines
- Say a directory is not a mount point yet and lookup instantiates an inode. Later user mounts something on that directory. When does client/server notice this change. I am assuming this is probably part of revalidation path.
I guess at least before this patch this is no different from any other filesystem change. Because st_dev+st_ino changed, it should basically look like the old directory was removed and a different one was put in its place.
Now, with this patch, we will return the old
st_inoto the guest, but internally virtiofsd will still use the submount’s st_dev/st_ino, so a newlo_inodeshould be created, and so fuse_dentry_revalidate()’s lookup should return a different node ID, resulting it to consider the entry expired.Besides,
fuse_dentry_revalidate()has a condition onIS_AUTOMOUNT(inode)!= flags &FUSE_ATTR_SUBMOUNT. Considering the previous paragraph, this doesn’t seem necessary to me, but it can’t hurt.Max
Signature · 1 line
Dr. David Alan Gilbert / [email protected] / Manchester, UK
Quoted 16 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.
Quoted 8 lines
There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted.
(Then, it will invoke getattr
and that stat(2) call will return the inode ID for the submount.)
Hi Max,
How are we sure that GETATTR() will always be called and that will allow us to return inode number in mounted filesystem (instead of parent filesystem). I thought GETATTR will be called only if cached attrs have expired. (1 second default for cache=auto). Otherwise stat() will fill inode->i_no from cache and return. And I am afraid that in that case we will return inode number from parent fs, instead of mounted fs.
Say following sequence of events happens pretty fast one after the other. Say /mnt/virtiofs/foo is a mount point in server but client has not created submount yet.
A. stat(/mnt/virtiofs/foo, AT_NO_AUTOMOUNT)
-> This should get inode number in parent filesystem on host and
store in guest inode->i_no and return to user space. Say inode in guest is called a_ino.
B. stat(/mnt/virtiofs/foo)
-> This should create submount and create new inode (say b_ino), using
properties from a_ino. IOW, this should copy a_ino->i_no to
b_ino->b_ino given current code, IIUC.-> Assume timeout has not happened and cached attrs have not expired.
-> And now b_ino->i_no (or ->orig_ino) will be returned to user space.
Am I missing something. Do we need to always expire inode attrs when we create submount so that client is forced to issue GETATTR.
Thanks
Vivek
Quoted 191 lines
Signed-off-by Max Reitz <[email protected]>--- tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++-- 1 file changed, 99 insertions(+), 5 deletions(-)tools/virtiofsd/passthrough_ll.c +99
-5@@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,return 0 ; } +/* +* Use readdir() to find mp_name's inode ID on the parent's filesystem. +* (For mount points, stat() will only return the inode ID on the +* filesystem mounted there, i.e. the root directory's inode ID. The +* mount point originally was a directory on the parent filesystem, +* though, and so has a different inode ID there. When passing +* submount information to the guest, we need to pass this other ID, +* so the guest can use it as the inode ID until the submount is +* auto-mounted. (At which point the guest will invoke getattr and +* find the inode ID on the submount.)) +* +* Return 0 on success, and -errno otherwise. *pino is set only in +* case of success. +*/ +static int get_mp_ino_on_parent (const struct lo_inode *dir,const char *mp_name, +ino_t *pino) +{ +int dirfd =-1 ; +int ret; +DIR *dp =NULL ; + + dirfd =openat (dir->fd,"." ,O_RDONLY ); +if (dirfd <0 ) { + ret = -errno; + goto out; + } + + dp =fdopendir (dirfd); +if (!dp) { + ret = -errno; + goto out; + } +/* Owned by dp now */ + dirfd =-1 ; + +while (true) { +struct dirent *de; + + errno =0 ; + de =readdir (dp); +if (!de) { + ret = errno ? -errno : -ENOENT ; + goto out; + } + +if (!strcmp (de->d_name, mp_name)) { + *pino = de->d_ino; + ret =0 ; + goto out; + } + } + +out: +if (dp) { +closedir (dp); + } +if (dirfd >=0 ) { +close (dirfd); + } +return ret; +} +/* * Increments nlookup on the inode on success. unref_inode_lolocked() must be * called eventually to decrement nlookup again. If inodep is non-NULL, the * inode pointer is stored and the caller must call lo_inode_put(). +* +* If parent_fs_st_ino is true, the entry is a mount point, and submounts are +* announced to the guest, set e->attr.st_ino to the entry's inode ID on its +* parent filesystem instead of its inode ID on the filesystem mounted on it. +* (For mount points, the entry encompasses two inodes: One on the parent FS, +* and one on the mounted FS (where it is the root node), so it has two inode +* IDs. When looking up entries, we should show the guest the parent FS's inode +* ID, because as long as the guest has not auto-mounted the submount, it should +* see that original ID. Once it does perform the auto-mount, it will invoke +* getattr and see the root node's inode ID.) */ static int lo_do_lookup (fuse_req_t req,fuse_ino_t parent,const char *name,struct fuse_entry_param *e, -struct lo_inode **inodep) +struct lo_inode **inodep, +bool parent_fs_st_ino) {int newfd;int res;@@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,struct lo_data *lo =lo_data (req);struct lo_inode *inode =NULL ;struct lo_inode *dir =lo_inode (req, parent); +ino_t ino_id_for_guest;if (inodep) { *inodep =NULL ;/* in case there is an error */ @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, goto out_err; } + ino_id_for_guest = e->attr.st_ino; +if (S_ISDIR (e->attr.st_mode) && lo->announce_submounts && (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) { e->attr_flags |=FUSE_ATTR_SUBMOUNT ; + +if (parent_fs_st_ino) { +/* +* Best effort, so ignore errors. +* Also note that using readdir() means there may be races: +* The directory entry we find (if any) may be different +* from newfd. Again, this is a best effort. Reporting +* the wrong inode ID to the guest is not catastrophic. +*/ +get_mp_ino_on_parent (dir, name, &ino_id_for_guest); + } } inode =lo_find (lo, &e->attr, mnt_id);@@ -1043,6 +1130,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, inode->nlookup =1 ; inode->fd = newfd; +/* +* For the inode key, use the dev/ino/mnt ID as reported by stat() +* (i.e. not ino_id_for_guest) +*/ inode->key.ino = e->attr.st_ino; inode->key.dev = e->attr.st_dev; inode->key.mnt_id = mnt_id;@@ -1058,6 +1149,9 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, } e->ino = inode->fuse_ino; +/* Report ino_id_for_guest to the guest */ + e->attr.st_ino = ino_id_for_guest; +/* Transfer ownership of inode pointer to caller or drop it */ if (inodep) { *inodep = inode;@@ -1104,7 +1198,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)return ; } - err =lo_do_lookup (req, parent, name, &e,NULL ); + err =lo_do_lookup (req, parent, name, &e,NULL , true);if (err) {fuse_reply_err (req, err); }else {@@ -1217,7 +1311,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent, goto out; } - saverr =lo_do_lookup (req, parent, name, &e,NULL ); + saverr =lo_do_lookup (req, parent, name, &e,NULL , false);if (saverr) { goto out; }@@ -1714,7 +1808,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,if (plus) {if (!is_dot_or_dotdot (name)) { - err =lo_do_lookup (req, ino, name, &e,NULL ); + err =lo_do_lookup (req, ino, name, &e,NULL , true);if (err) { goto error; }@@ -1936,7 +2030,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name, goto out; } - err =lo_do_lookup (req, parent, name, &e, &inode); + err =lo_do_lookup (req, parent, name, &e, &inode, false);if (err) { goto out; }Signature · 1 line
2.31.1
Quoted 49 lines · Vivek Goyal
Quoted 16 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.Quoted 8 lines
There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted.
(Then, it will invoke getattr
and that stat(2) call will return the inode ID for the submount.)Hi Max,
How are we sure that
GETATTR()will always be called and that will allow us to return inode number in mounted filesystem (instead of parent filesystem). I thought GETATTR will be called only if cached attrs have expired. (1 second default for cache=auto). Otherwisestat()will fillinode->i_nofrom cache and return. And I am afraid that in that case we will return inode number from parent fs, instead of mounted fs.Say following sequence of events happens pretty fast one after the other. Say
/mnt/virtiofs/foois a mount point in server but client has not created submount yet.A.
stat(/mnt/virtiofs/foo, AT_NO_AUTOMOUNT)
-> This should get inode number in parent filesystem on host and
store in guestinode->i_noand return to user space. Say inode in guest is calleda_ino.
B. stat(/mnt/virtiofs/foo)
-> This should create submount and create new inode (sayb_ino), usingproperties from a_ino. IOW, this should copy a_ino->i_no to b_ino->b_ino given current code, IIUC.
Quoted 6 lines
-> Assume timeout has not happened and cached attrs have not expired.
-> And now
b_ino->i_no(or ->orig_ino) will be returned to user space.Am I missing something. Do we need to always expire inode attrs when we create submount so that client is forced to issue GETATTR.
Looks like while initialzing b_ino, we are setting attr_valid=0, which should set fi->i_time=0 and force issuing GETATTR later.
fuse_fill_super_submount()
root = fuse_iget(sb, parent_fi->nodeid, 0, &root_attr, 0, 0);
^
fuse_iget(attr_valid=0)
fuse_change_attributes(attr_valid=0)
fuse_change_attributes_common(attr_valid=0)
fi->i_time = attr_valid;So may be this will force GETATTR and fetch new inode id when second stat() is called.
Thanks
Vivek
Quoted 196 lines
Quoted 190 lines
Signed-off-by Max Reitz <[email protected]>--- tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++-- 1 file changed, 99 insertions(+), 5 deletions(-)tools/virtiofsd/passthrough_ll.c +99
-5@@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,return 0 ; } +/* +* Use readdir() to find mp_name's inode ID on the parent's filesystem. +* (For mount points, stat() will only return the inode ID on the +* filesystem mounted there, i.e. the root directory's inode ID. The +* mount point originally was a directory on the parent filesystem, +* though, and so has a different inode ID there. When passing +* submount information to the guest, we need to pass this other ID, +* so the guest can use it as the inode ID until the submount is +* auto-mounted. (At which point the guest will invoke getattr and +* find the inode ID on the submount.)) +* +* Return 0 on success, and -errno otherwise. *pino is set only in +* case of success. +*/ +static int get_mp_ino_on_parent (const struct lo_inode *dir,const char *mp_name, +ino_t *pino) +{ +int dirfd =-1 ; +int ret; +DIR *dp =NULL ; + + dirfd =openat (dir->fd,"." ,O_RDONLY ); +if (dirfd <0 ) { + ret = -errno; + goto out; + } + + dp =fdopendir (dirfd); +if (!dp) { + ret = -errno; + goto out; + } +/* Owned by dp now */ + dirfd =-1 ; + +while (true) { +struct dirent *de; + + errno =0 ; + de =readdir (dp); +if (!de) { + ret = errno ? -errno : -ENOENT ; + goto out; + } + +if (!strcmp (de->d_name, mp_name)) { + *pino = de->d_ino; + ret =0 ; + goto out; + } + } + +out: +if (dp) { +closedir (dp); + } +if (dirfd >=0 ) { +close (dirfd); + } +return ret; +} +/* * Increments nlookup on the inode on success. unref_inode_lolocked() must be * called eventually to decrement nlookup again. If inodep is non-NULL, the * inode pointer is stored and the caller must call lo_inode_put(). +* +* If parent_fs_st_ino is true, the entry is a mount point, and submounts are +* announced to the guest, set e->attr.st_ino to the entry's inode ID on its +* parent filesystem instead of its inode ID on the filesystem mounted on it. +* (For mount points, the entry encompasses two inodes: One on the parent FS, +* and one on the mounted FS (where it is the root node), so it has two inode +* IDs. When looking up entries, we should show the guest the parent FS's inode +* ID, because as long as the guest has not auto-mounted the submount, it should +* see that original ID. Once it does perform the auto-mount, it will invoke +* getattr and see the root node's inode ID.) */ static int lo_do_lookup (fuse_req_t req,fuse_ino_t parent,const char *name,struct fuse_entry_param *e, -struct lo_inode **inodep) +struct lo_inode **inodep, +bool parent_fs_st_ino) {int newfd;int res;@@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,struct lo_data *lo =lo_data (req);struct lo_inode *inode =NULL ;struct lo_inode *dir =lo_inode (req, parent); +ino_t ino_id_for_guest;if (inodep) { *inodep =NULL ;/* in case there is an error */ @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, goto out_err; } + ino_id_for_guest = e->attr.st_ino; +if (S_ISDIR (e->attr.st_mode) && lo->announce_submounts && (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) { e->attr_flags |=FUSE_ATTR_SUBMOUNT ; + +if (parent_fs_st_ino) { +/* +* Best effort, so ignore errors. +* Also note that using readdir() means there may be races: +* The directory entry we find (if any) may be different +* from newfd. Again, this is a best effort. Reporting +* the wrong inode ID to the guest is not catastrophic. +*/ +get_mp_ino_on_parent (dir, name, &ino_id_for_guest); + } } inode =lo_find (lo, &e->attr, mnt_id);@@ -1043,6 +1130,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, inode->nlookup =1 ; inode->fd = newfd; +/* +* For the inode key, use the dev/ino/mnt ID as reported by stat() +* (i.e. not ino_id_for_guest) +*/ inode->key.ino = e->attr.st_ino; inode->key.dev = e->attr.st_dev; inode->key.mnt_id = mnt_id;@@ -1058,6 +1149,9 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, } e->ino = inode->fuse_ino; +/* Report ino_id_for_guest to the guest */ + e->attr.st_ino = ino_id_for_guest; +/* Transfer ownership of inode pointer to caller or drop it */ if (inodep) { *inodep = inode;@@ -1104,7 +1198,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)return ; } - err =lo_do_lookup (req, parent, name, &e,NULL ); + err =lo_do_lookup (req, parent, name, &e,NULL , true);if (err) {fuse_reply_err (req, err); }else {@@ -1217,7 +1311,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent, goto out; } - saverr =lo_do_lookup (req, parent, name, &e,NULL ); + saverr =lo_do_lookup (req, parent, name, &e,NULL , false);if (saverr) { goto out; }@@ -1714,7 +1808,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,if (plus) {if (!is_dot_or_dotdot (name)) { - err =lo_do_lookup (req, ino, name, &e,NULL ); + err =lo_do_lookup (req, ino, name, &e,NULL , true);if (err) { goto error; }@@ -1936,7 +2030,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name, goto out; } - err =lo_do_lookup (req, parent, name, &e, &inode); + err =lo_do_lookup (req, parent, name, &e, &inode, false);if (err) { goto out; }Signature · 1 line
2.31.1_______________________________________________
Virtio-fs mailing list
[email protected]
https://listman.redhat.com/mailman/listinfo/virtio-fs
Quoted 50 lines · Vivek Goyal
Quoted 49 lines · Vivek Goyal
Quoted 16 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.Quoted 8 lines
There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted.
(Then, it will invoke getattr
and that stat(2) call will return the inode ID for the submount.)Hi Max,
How are we sure that
GETATTR()will always be called and that will allow us to return inode number in mounted filesystem (instead of parent filesystem). I thought GETATTR will be called only if cached attrs have expired. (1 second default for cache=auto). Otherwisestat()will fillinode->i_nofrom cache and return. And I am afraid that in that case we will return inode number from parent fs, instead of mounted fs.Say following sequence of events happens pretty fast one after the other. Say
/mnt/virtiofs/foois a mount point in server but client has not created submount yet.A.
stat(/mnt/virtiofs/foo, AT_NO_AUTOMOUNT)-> This should get inode number in parent filesystem on host and store in guest inode->i_no and return to user space. Say inode in guest is called a_ino. B. stat(/mnt/virtiofs/foo) -> This should create submount and create new inode (say b_ino), using properties from a_ino. IOW, this should copy a_ino->i_no to b_ino->b_ino given current code, IIUC.
Quoted 3 lines
Quoted 3 lines
-> Assume timeout has not happened and cached attrs have not expired. -> And now b_ino->i_no (or ->orig_ino) will be returned to user space.
Well, I mean, this sounds easy enough to test. For example, this passes for me:
count=1000
root_st_ino=128
tag=host
mountpoint=/mnt
submount_path=submount
for i in $(seq $count)
do
mount -t virtiofs $tag $mountpoint || break
if [ $(stat -c '%i' $mountpoint/$submount_path) -eq $root_st_ino ]
then
echo 'fail 0'
break
fi
ls $mountpoint/$submount_path > /dev/null
if [ $(stat -c '%i' $mountpoint/$submount_path) -ne $root_st_ino ]
then
echo 'fail 1'
break
fi
umount $mountpoint || breakdone
if [ $i -ne $count ]
then
echo 'Something failed'
else
echo 'OK'
fi
Quoted 14 lines
Quoted 2 lines
Am I missing something. Do we need to always expire inode attrs when we create submount so that client is forced to issue GETATTR.
Looks like while initialzing
b_ino, we are setting attr_valid=0, which should set fi->i_time=0 and force issuing GETATTR later.
fuse_fill_super_submount()root = fuse_iget(sb, parent_fi->nodeid, 0, &root_attr, 0, 0); ^ fuse_iget(attr_valid=0) fuse_change_attributes(attr_valid=0) fuse_change_attributes_common(attr_valid=0) fi->i_time = attr_valid;
Quoted 2 lines
So may be this will force GETATTR and fetch new inode id when second
stat()is called.
i_time is at least what fuse_update_get_attr() uses to decide whether to invoke GETATTR or not – although AT_STATX_DONT_SYNC can override that, but I don’t think that’s a problem. If i_time is 0, that function will always invoke GETATTR (unless AT_STATX_DONT_SYNC).
So I think it works in practice. When the inode ID is looked up through some stat-y function, this should go through fuse_update_get_attr(), which will fetch the st_ino on the submount. There is still i_ino, though...
To be absolutely certain, we could invoke fuse_update_attributes() in fuse_fill_super_submount(), but then again, fuse_fill_super_common() doesn’t do that either for its root node. It just initializes i_ino to FUSE_ROOT_ID, i.e. 1.
Max
Quoted 16 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.
Quoted 6 lines
There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr and that stat(2) call will return the inode ID for the submount.)
[ CC miklos ]
Hi Max,
Though we discussed this in chat room, I am still responding to this email with the concern I have, so that there is a record of it.
So with this patch for FUSE_LOOKUP we always return submount's parentinode id and with GETATTR request we return actual inode id of submount. That kind of bothers me a bit as we are assuming that there is always going to be a GETATTR request after FUSE_LOOKUP. FUSE_LOOKUP itself has attrs returned with it and it might happen that after FUSE_LOOKUP, FUSE_GETATTR might not be called at all because FUSE_LOOKUP itself got the latest updated attrs with certain timeout.
For example, if I call stat on a normal file (not submount), I see that after FUSE_LOOKUP, no FUSE_GETATTR request is going and fuse_update_get_attr() is using attrs from locally cached inode attrs.
But same thing does not seem to be happening in case of submount. Once submount is created in guest, I see that we never seem to be calling ->revalidate() on newly created dentry of submount root. I am not sure why. And that means we don't do FUSE_LOOKUP and that means FUSE_GETATTR always gets called.
I am not sure if this is a bug or expected behavior. I am not confident that we can rely on this behavior of submount dentries.
Ccing Miklos. He might have thoughts on this.
As we discussed, may be it is a better idea to create two inodes in virtiofsd (like we do in guest). One for submount parent and one for actual submount.
Thanks
Vivek
Quoted 191 lines
Signed-off-by Max Reitz <[email protected]>--- tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++-- 1 file changed, 99 insertions(+), 5 deletions(-)tools/virtiofsd/passthrough_ll.c +99
-5@@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,return 0 ; } +/* +* Use readdir() to find mp_name's inode ID on the parent's filesystem. +* (For mount points, stat() will only return the inode ID on the +* filesystem mounted there, i.e. the root directory's inode ID. The +* mount point originally was a directory on the parent filesystem, +* though, and so has a different inode ID there. When passing +* submount information to the guest, we need to pass this other ID, +* so the guest can use it as the inode ID until the submount is +* auto-mounted. (At which point the guest will invoke getattr and +* find the inode ID on the submount.)) +* +* Return 0 on success, and -errno otherwise. *pino is set only in +* case of success. +*/ +static int get_mp_ino_on_parent (const struct lo_inode *dir,const char *mp_name, +ino_t *pino) +{ +int dirfd =-1 ; +int ret; +DIR *dp =NULL ; + + dirfd =openat (dir->fd,"." ,O_RDONLY ); +if (dirfd <0 ) { + ret = -errno; + goto out; + } + + dp =fdopendir (dirfd); +if (!dp) { + ret = -errno; + goto out; + } +/* Owned by dp now */ + dirfd =-1 ; + +while (true) { +struct dirent *de; + + errno =0 ; + de =readdir (dp); +if (!de) { + ret = errno ? -errno : -ENOENT ; + goto out; + } + +if (!strcmp (de->d_name, mp_name)) { + *pino = de->d_ino; + ret =0 ; + goto out; + } + } + +out: +if (dp) { +closedir (dp); + } +if (dirfd >=0 ) { +close (dirfd); + } +return ret; +} +/* * Increments nlookup on the inode on success. unref_inode_lolocked() must be * called eventually to decrement nlookup again. If inodep is non-NULL, the * inode pointer is stored and the caller must call lo_inode_put(). +* +* If parent_fs_st_ino is true, the entry is a mount point, and submounts are +* announced to the guest, set e->attr.st_ino to the entry's inode ID on its +* parent filesystem instead of its inode ID on the filesystem mounted on it. +* (For mount points, the entry encompasses two inodes: One on the parent FS, +* and one on the mounted FS (where it is the root node), so it has two inode +* IDs. When looking up entries, we should show the guest the parent FS's inode +* ID, because as long as the guest has not auto-mounted the submount, it should +* see that original ID. Once it does perform the auto-mount, it will invoke +* getattr and see the root node's inode ID.) */ static int lo_do_lookup (fuse_req_t req,fuse_ino_t parent,const char *name,struct fuse_entry_param *e, -struct lo_inode **inodep) +struct lo_inode **inodep, +bool parent_fs_st_ino) {int newfd;int res;@@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,struct lo_data *lo =lo_data (req);struct lo_inode *inode =NULL ;struct lo_inode *dir =lo_inode (req, parent); +ino_t ino_id_for_guest;if (inodep) { *inodep =NULL ;/* in case there is an error */ @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, goto out_err; } + ino_id_for_guest = e->attr.st_ino; +if (S_ISDIR (e->attr.st_mode) && lo->announce_submounts && (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) { e->attr_flags |=FUSE_ATTR_SUBMOUNT ; + +if (parent_fs_st_ino) { +/* +* Best effort, so ignore errors. +* Also note that using readdir() means there may be races: +* The directory entry we find (if any) may be different +* from newfd. Again, this is a best effort. Reporting +* the wrong inode ID to the guest is not catastrophic. +*/ +get_mp_ino_on_parent (dir, name, &ino_id_for_guest); + } } inode =lo_find (lo, &e->attr, mnt_id);@@ -1043,6 +1130,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, inode->nlookup =1 ; inode->fd = newfd; +/* +* For the inode key, use the dev/ino/mnt ID as reported by stat() +* (i.e. not ino_id_for_guest) +*/ inode->key.ino = e->attr.st_ino; inode->key.dev = e->attr.st_dev; inode->key.mnt_id = mnt_id;@@ -1058,6 +1149,9 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name, } e->ino = inode->fuse_ino; +/* Report ino_id_for_guest to the guest */ + e->attr.st_ino = ino_id_for_guest; +/* Transfer ownership of inode pointer to caller or drop it */ if (inodep) { *inodep = inode;@@ -1104,7 +1198,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)return ; } - err =lo_do_lookup (req, parent, name, &e,NULL ); + err =lo_do_lookup (req, parent, name, &e,NULL , true);if (err) {fuse_reply_err (req, err); }else {@@ -1217,7 +1311,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent, goto out; } - saverr =lo_do_lookup (req, parent, name, &e,NULL ); + saverr =lo_do_lookup (req, parent, name, &e,NULL , false);if (saverr) { goto out; }@@ -1714,7 +1808,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,if (plus) {if (!is_dot_or_dotdot (name)) { - err =lo_do_lookup (req, ino, name, &e,NULL ); + err =lo_do_lookup (req, ino, name, &e,NULL , true);if (err) { goto error; }@@ -1936,7 +2030,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name, goto out; } - err =lo_do_lookup (req, parent, name, &e, &inode); + err =lo_do_lookup (req, parent, name, &e, &inode, false);if (err) { goto out; }Signature · 1 line
2.31.1
Quoted 44 lines · Vivek Goyal
Quoted 16 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.Quoted 6 lines
There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr and that stat(2) call will return the inode ID for the submount.)
[ CC miklos ]
Hi Max,
Though we discussed this in chat room, I am still responding to this email with the concern I have, so that there is a record of it.
So with this patch for
FUSE_LOOKUPwe always return submount's parentinode id and with GETATTR request we return actual inode id of submount. That kind of bothers me a bit as we are assuming that there is always going to be a GETATTR request afterFUSE_LOOKUP.FUSE_LOOKUPitself has attrs returned with it and it might happen that afterFUSE_LOOKUP,FUSE_GETATTRmight not be called at all becauseFUSE_LOOKUPitself got the latest updated attrs with certain timeout.For example, if I call stat on a normal file (not submount), I see that after
FUSE_LOOKUP, noFUSE_GETATTRrequest is going andfuse_update_get_attr()is using attrs from locally cached inode attrs.
Quoted 5 lines
But same thing does not seem to be happening in case of submount. Once submount is created in guest, I see that we never seem to be calling ->revalidate() on newly created dentry of submount root. I am not sure why. And that means we don't do
FUSE_LOOKUPand that meansFUSE_GETATTRalways gets called.
Yes, this sounds normal.
The lookup sequence for "/mnt/virtiofs/dir1/submount/file" will be:
LOOKUP(1, "dir")
create inode I1 in sb1
create dentry "dir" with inode I1 in sb1LOOKUP(I1, "submount")
create inode I2 in sb1, set S_AUTOMOUNT
create dentry "submount" with inode I2 in sb1
automount triggered:
create sb2
create inode I2 in sb2
create dentry "/" with inode I2 in sb2
GETATTR(I2)
fill inode I2LOOKUP(I2, "file")
create inode I3
create dentry "file" with inode I3 in sb2
Notice how there's two inodes numbered I2, but in separate sb's. However the server has only the notion of a single I2 inode which is the root of the submount, since the mountpoint is not visible (except for d_ino in readdir()).
Now AFAICS what this patch does is set the inode number in the attributes returned by LOOKUP(I1, "submount") to the covered inode, so
that AT_NO_AUTOMOUNT stat will return the correct value. While this
seems to work, it's not a fundamental fix to the problem, since the attributes on sb1/I2 will time out and the next stat(..., AT_NO_AUTOMOUNT) will trigger a GETATTR request, which will return the inode number of the submount root.
Solving this properly would mean that the server would have to generate separate nodeid's for the mountpoint and the submount root and the protocol would have to be extended so that this information could be transferred to the client.
Not sure whether this is worth it or not.
Thanks,
Miklos
Quoted 24 lines · Miklos Szeredi
Quoted 23 lines · Vivek Goyal
Quoted 22 lines · Max Reitz
Mount point directories represent two inodes: On one hand, they are a normal directory on their parent filesystem. On the other, they are the root node of the filesystem mounted there. Thus, they have two inode IDs.
Right now, we only report the latter inode ID (i.e. the inode ID of the mounted filesystem's root node). This is fine once the guest has auto-mounted a submount there (so this inode ID goes with a device ID that is distinct from the parent filesystem), but before the auto-mount, they have the device ID of the parent and the inode ID for the submount. This is problematic because this is likely exactly the same st_dev/st_ino combination as the parent filesystem's root node. This leads to problems for example with
find, which will thus complain about a filesystem loop if it has visited the parent filesystem's root node before, and then refuse to descend into the submount.There is a way to find the mount directory's original inode ID, and that is to readdir(3) the parent directory, look for the mount directory, and read the dirent.d_ino field. Using this, we can let lookup and readdirplus return that original inode ID, which the guest will thus show until the submount is auto-mounted. (Then, it will invoke getattr and that stat(2) call will return the inode ID for the submount.)
Quoted 6 lines
Quoted 6 lines
[ CC miklos ]
Hi Max,
Though we discussed this in chat room, I am still responding to this email with the concern I have, so that there is a record of it.
That sounds scary :)
Quoted 12 lines
Quoted 12 lines
So with this patch for
FUSE_LOOKUPwe always return submount's parentinode id and with GETATTR request we return actual inode id of submount. That kind of bothers me a bit as we are assuming that there is always going to be a GETATTR request afterFUSE_LOOKUP.FUSE_LOOKUPitself has attrs returned with it and it might happen that afterFUSE_LOOKUP,FUSE_GETATTRmight not be called at all becauseFUSE_LOOKUPitself got the latest updated attrs with certain timeout.For example, if I call stat on a normal file (not submount), I see that after
FUSE_LOOKUP, noFUSE_GETATTRrequest is going andfuse_update_get_attr()is using attrs from locally cached inode attrs.
Quoted 5 lines
Quoted 5 lines
But same thing does not seem to be happening in case of submount. Once submount is created in guest, I see that we never seem to be calling ->revalidate() on newly created dentry of submount root. I am not sure why. And that means we don't do
FUSE_LOOKUPand that meansFUSE_GETATTRalways gets called.
Even if it worked reliably, I have to admit it’s kind of relying on at most implementation-defined behavior. Having two inodes would definitely be the right solution.
Quoted 25 lines
Yes, this sounds normal.
The lookup sequence for "
/mnt/virtiofs/dir1/submount/file" will be:
LOOKUP(1, "dir")
create inode I1 in sb1
create dentry "dir" with inode I1 in sb1LOOKUP(I1, "submount")
create inode I2 in sb1, setS_AUTOMOUNTcreate dentry "submount" with inode I2 in sb1 automount triggered:
create sb2
create inode I2 in sb2
create dentry "/" with inode I2 in sb2
GETATTR(I2)
fill inode I2LOOKUP(I2, "file")
create inode I3
create dentry "file" with inode I3 in sb2Notice how there's two inodes numbered I2, but in separate sb's. However the server has only the notion of a single I2 inode which is the root of the submount, since the mountpoint is not visible (except for
d_inoinreaddir()).
Quoted 7 lines
Now AFAICS what this patch does is set the inode number in the attributes returned by
LOOKUP(I1, "submount")to the covered inode, so
thatAT_NO_AUTOMOUNTstat will return the correct value. While this
seems to work, it's not a fundamental fix to the problem, since the attributes on sb1/I2 will time out and the nextstat(..., AT_NO_AUTOMOUNT)will trigger a GETATTR request, which will return the inode number of the submount root.
Ah, yeah.
Quoted 4 lines
Solving this properly would mean that the server would have to generate separate nodeid's for the mountpoint and the submount root and the protocol would have to be extended so that this information could be transferred to the client.
Yes, we’d somehow need to do a separate lookup for the root inode of the submount...
Quoted 1 line
Not sure whether this is worth it or not.
I’m wondering the same. This series was mostly the result of an incidental finding and seeing that getting it to work and do what I want seemed to be pretty easy. Turns out doing something right can never really be easy...
But we have already decided that we don’t deem the inode ID problem too important (not least considering NFS has the same issue), so fixing it is not really top priority. Maybe I’ll get back to it, but I think for now I consider it on the backlog.
Max
PATCH 2/3 virtiofs_submounts.py: Do not generate ssh key
In reply to Max ReitzSince c0c5a7f18e623b8f6eb, avocado_qemu provides an ssh key by default. There is no need to generate one in the virtiofs_submounts test. (In fact, it currently is harmful, because e8197c6e0c56aff83 made LinuxTest expect ssh_pubkey to be a file path and not the file content, but virtiofs_submounts provides the latter.)
--- tests/acceptance/virtiofs_submounts.py | 10 ++-------- 1 file changed, 2 insertions(+), 8 deletions(-)
tests/acceptance/virtiofs_submounts.py +2 -8
@@ -220,7 +220,7 @@ def live_cleanup(self): self.run(('bash', self.get_data('cleanup.sh'), scratch_dir)) @skipUnless(*has_cmds(('sudo -n', ('sudo', '-n', 'true')), - 'ssh-keygen', 'bash', 'losetup', 'mkfs.xfs', 'mount')) + 'bash', 'losetup', 'mkfs.xfs', 'mount')) def setUp(self): vmlinuz = self.params.get('vmlinuz') if vmlinuz is None:
@@ -242,13 +242,7 @@ def setUp(self): self.seed = self.params.get('seed') - self.ssh_key = os.path.join(self.workdir, 'id_ed25519') - - self.run(('ssh-keygen', '-N', '', '-t', 'ed25519', '-f', self.ssh_key)) - - pubkey = open(self.ssh_key + '.pub').read() - - super(VirtiofsSubmountsTest, self).setUp(pubkey) + super(VirtiofsSubmountsTest, self).setUp() if len(vmlinuz) > 0: self.vm.add_args('-kernel', vmlinuz,
Signature · 1 line
2.31.1
PATCH 3/3 virtiofs_submounts.py: Check `find`
In reply to Max ReitzThe guest test script contained a lengthy section on why we cannot just run find to auto-mount all submounts. With HEAD^^, that should work now, so replace it and the recursively_visit() function by a lengthy section explaining the history, and a find.
(Also really check that find will not complain about anything.)
--- .../virtiofs_submounts.py.data/guest.sh | 56 +++++++------------ 1 file changed, 21 insertions(+), 35 deletions(-)
tests/acceptance/virtiofs_submounts.py.data/guest.sh +21 -35
@@ -19,41 +19,27 @@ fi cd "$shared_dir" -# FIXME: This should not be necessary, but it is. In order for all -# submounts to be proper mount points, we need to visit them. -# (Before we visit them, they will not be auto-mounted, and so just -# appear as normal directories, with the catch that their st_ino will -# be the st_ino of the filesystem they host, while the st_dev will -# still be the st_dev of the parent.) -# `find` does not work, because it will refuse to touch the mount -# points as long as they are not mounted; their st_dev being shared -# with the parent and st_ino just being the root node's inode ID -# will practically ensure that this node exists elsewhere on the -# filesystem, and `find` is required to recognize loops and not to -# follow them. -# Thus, we have to manually visit all nodes first. - -mnt_i=0 - -function recursively_visit() -{ - pushd "$1" >/dev/null - for entry in *; do - if [[ "$entry" == mnt* ]]; then - mnt_i=$((mnt_i + 1)) - printf "Triggering auto-mount $mnt_i...\r" - fi - - if [ -d "$entry" ]; then - recursively_visit "$entry" - fi - done - popd >/dev/null -} - -recursively_visit . -echo - +# See whether `find` complains about anything, like file system loops, +# by looking for a file that does not exist (so the output should be +# empty). +# (Historically, for mount points, virtiofsd reported only the inode ID +# in submount, i.e. the submount root's inode ID. However, while the +# submount is not yet auto-mounted in the guest, it would have the +# parent's device ID, and so would have the same st_dev/st_ino +# combination as the parent filesystem's root. This would lead to +# `find` reporting file system loops. +# This has been fixed so that virtiofsd reports the mount point node's +# inode ID in the parent filesystem, and when the guest auto-mounts the +# submount, it will only then see the inode ID in that FS.) +# +# As a side-effect, this `find` auto-mounts all submounts by visiting +# the whole tree. +find_output=$(find -name there-is-no-such-file 2>&1) +if [ -n "$find_output" ]; then + echo "Error: find has reported errors or warnings:" >&2 + echo "$find_output" >&2 + exit 1 +fi if [ -n "$(find -name not-mounted)" ]; then echo "Error: not-mounted files visible on mount points:" >&2
Signature · 1 line
2.31.1
cover virtiofsd: Find original inode ID of mount points
In reply to Max ReitzSorry, forgot to CC the virtio-fs list. I hope forwarding the cover letter is enough...
Here’s the link to the qemu-devel archive:
https://lists.nongnu.org/archive/html/qemu-devel/2021-05/msg03366.html
-------- Forwarded Message --------
Subject: [PATCH 0/3] virtiofsd: Find original inode ID of mount points
Date: Wed, 12 May 2021 14:55:41 +0200
From: Max Reitz <[email protected]>
To: [email protected]
Copy (CC): Max Reitz <[email protected]>, Dr . David Alan Gilbert <[email protected]>, Stefan Hajnoczi <[email protected]>
Hi,
Not announcing submounts to the guest may lead to duplicated st_dev/st_ino combinations, because inodes on different filesystems (different st_dev) may share the same inode ID (st_ino). If the guest only sees a single st_dev, those inodes will appear to have the same st_dev/st_ino combination.
Announcing submounts is supposed to solve this problem by making the guest report different st_dev IDs for different filesystems.
However, there is one loop hole: Submounts are implemented as auto-mounts, meaning when the virtio-fs filesystem is mounted, the submounts will not be mounted immediately. In the guest, it is possible to stat() these mount points with AT_NO_AUTOMOUNT to receive information without mounting them, so they will then show whatever st_ino virtiofsd passes, and the st_dev of the parent filesystem.
Unfortunately, as far as we understood, the only st_ino that virtiofsd could inquire was the one on the submounted filesystem, i.e. the st_ino of that FS’s root node.
Thus, we again got a collision: In said case, the guest would see st_dev of the parent FS, but st_ino of the submounted FS. This is very likely to be the same st_dev/st_ino combination as the root node of the parent FS.
For nested mount structures, this can be reproduced with find:
Mounting several filesystems under each other, passing everything into a guest, mounting the root virtio-fs FS there, and then invoking find would likely result in it complaining about filesystem loops and refusing to visit the submount points. (These loops are reported because it takes notes of st_dev/st_ino combinations, and then reports a loop when some combination reappears.) This can only be fixed by forcing all submounts to be (auto-)mounted.
What we’d need to do is report the inode ID of the mount point directory that it has on the parent filesystem to the guest, until the submount is auto-mounted there. It’s just that we thought there was no way to inquire this parent FS st_ino.
It turns out that our understand was wrong, though: There is a way, namely readdir(). The dirent.d_ino field represents (in practice) the st_ino of some directory entry on the directory’s filesystem, and so is exactly the value we want to give to the guest.
Let’s do that.
Max Reitz (3):
virtiofsd: Find original inode ID of mount points virtiofs_submounts.py: Do not generate ssh key virtiofs_submounts.py: Check find
tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++- tests/acceptance/virtiofs_submounts.py | 10 +- .../virtiofs_submounts.py.data/guest.sh | 56 ++++------ 3 files changed, 122 insertions(+), 48 deletions(-)
Signature · 1 line
2.31.1