cover iio: magnetometer: add support for Si7210

This patch series adds support for the Si7210 Hall effect I2C sensor. The driver currently supports the basic functionalities (i.e. making temperature and magnetic field measurements and changing the measurements scale) but I plan to add support for some other features in the future as well (e.g. the digital output interrupt).

Antoni Pokusinski (2):
dt-bindings: iio: magnetometer: add binding for Si7210
iio: magnetometer: si7210: add driver for Si7210

 .../iio/magnetometer/silabs,si7210.yaml       |  44 ++
 drivers/iio/magnetometer/Kconfig              |  11 +
 drivers/iio/magnetometer/Makefile             |   2 +
 drivers/iio/magnetometer/si7210.c             | 412 ++++++++++++++++++
 4 files changed, 469 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/iio/magnetometer/silabs,si7210.yaml
 create mode 100644 drivers/iio/magnetometer/si7210.c
Signature · 1 line
2.45.2
#1 lore raw

PATCH 1/2 dt-bindings: iio: magnetometer: add binding for Si7210

Silicon Labs Si7210 is an I2C Hall effect magnetic position and temperature sensor.

---
 .../iio/magnetometer/silabs,si7210.yaml       | 44 +++++++++++++++++++
 1 file changed, 44 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/iio/magnetometer/silabs,si7210.yaml
Documentation/devicetree/bindings/iio/magnetometer/silabs,si7210.yaml new file +44 -0
new file mode 100644
index 000000000000..ef29d12811e7
@@ -0,0 +1,44 @@
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/magnetometer/silabs,si7210.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Si7210 magnetic position and temperature sensor
+
+maintainers:
+  - Antoni Pokusinski <[email protected]>
+
+description: |
+  Silabs Si7210 I2C Hall effect magnetic position and temperature sensor.
+  https://www.silabs.com/documents/public/data-sheets/si7210-datasheet.pdf
+
+properties:
+  compatible:
+    const: silabs,si7210
+
+  reg:
+    maxItems: 1
+
+  interrupts:
+    maxItems: 1
+
+required:
+  - compatible
+  - reg
+
+additionalProperties: false
+
+examples:
+  - |
+    #include <dt-bindings/interrupt-controller/irq.h>
+    i2c {
+        #address-cells = <1>;
+        #size-cells = <0>;
+        magnetometer@30 {
+            compatible = "silabs,si7210";
+            reg = <0x30>;
+            interrupt-parent = <&gpio1>;
+            interrupts = <4 IRQ_TYPE_EDGE_FALLING>;
+        };
+    };
Signature · 1 line
2.45.2
#2 lore raw

Re: [PATCH 1/2] dt-bindings: iio: magnetometer: add binding for Si7210

Quoted 29 lines · Antoni Pokusinski

Silicon Labs Si7210 is an I2C Hall effect magnetic position and temperature sensor.

---
 .../iio/magnetometer/silabs,si7210.yaml       | 44 +++++++++++++++++++
 1 file changed, 44 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/iio/magnetometer/silabs,si7210.yaml
Documentation/devicetree/bindings/iio/magnetometer/silabs,si7210.yaml new file +14 -0
new file mode 100644
index 000000000000..ef29d12811e7
@@ -0,0 +1,44 @@
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/magnetometer/silabs,si7210.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Si7210 magnetic position and temperature sensor
+
+maintainers:
+  - Antoni Pokusinski <[email protected]>
+
+description: |
+  Silabs Si7210 I2C Hall effect magnetic position and temperature sensor.
+  https://www.silabs.com/documents/public/data-sheets/si7210-datasheet.pdf

Documentation/devicetree/bindings/iio/magnetometer/silabs,si7210.yaml line 24

Quoted 10 lines
Documentation/devicetree/bindings/iio/magnetometer/silabs,si7210.yaml new file +10 -0
+
+properties:
+  compatible:
+    const: silabs,si7210
+
+  reg:
+    maxItems: 1
+
+  interrupts:
+    maxItems: 1

You miss the vdd-supply, because otherwise it would fit into trivial-devices.

Best regards,
Krzysztof

#3 lore raw

PATCH 2/2 iio: magnetometer: si7210: add driver for Si7210

In reply to Antoni Pokusinski

Silicon Labs Si7210 is an I2C Hall effect magnetic position and temperature sensor. The driver supports the following functionalities:
* reading the temperature measurements
* reading the magnetic field measurements in a single-shot mode
* choosing the magnetic field measurement scale (20 or 200 mT)

---
 drivers/iio/magnetometer/Kconfig  |  11 +
 drivers/iio/magnetometer/Makefile |   2 +
 drivers/iio/magnetometer/si7210.c | 412 ++++++++++++++++++++++++++++++
 3 files changed, 425 insertions(+)
 create mode 100644 drivers/iio/magnetometer/si7210.c
drivers/iio/magnetometer/Kconfig +11 -0
index 7177cd1d67cb..3debf1320ad1 100644
@@ -235,6 +235,17 @@ config SENSORS_RM3100_SPI
 	  To compile this driver as a module, choose M here: the module
 	  will be called rm3100-spi.
 
+config SI7210
+	tristate "SI7210 Hall effect sensor"
+	depends on I2C
+	select REGMAP_I2C
+	help
+	  Say Y here to add support for the SI7210 Hall effect sensor.
+
+	  This driver can also be compiled as a module.
+	  To compile this driver as a module, choose M here: the module
+	  will be called si7210.
+
 config TI_TMAG5273
 	tristate "TI TMAG5273 Low-Power Linear 3D Hall-Effect Sensor"
 	depends on I2C
drivers/iio/magnetometer/Makefile +2 -0
index 3e4c2ecd9adf..58f32a855494 100644
@@ -31,6 +31,8 @@ obj-$(CONFIG_SENSORS_RM3100)		+= rm3100-core.o
 obj-$(CONFIG_SENSORS_RM3100_I2C)	+= rm3100-i2c.o
 obj-$(CONFIG_SENSORS_RM3100_SPI)	+= rm3100-spi.o
 
+obj-$(CONFIG_SI7210) += si7210.o
+
 obj-$(CONFIG_TI_TMAG5273)		+= tmag5273.o
 
 obj-$(CONFIG_YAMAHA_YAS530)		+= yamaha-yas530.o
drivers/iio/magnetometer/si7210.c new file +412 -0

412 lines not on this page · raw message

Signature · 1 line
2.45.2
maintainer
#4 lore raw

Re: [PATCH 2/2] iio: magnetometer: si7210: add driver for Si7210

Quoted 7 lines · On Tue, 31 Dec 2024 14:25:13 +0100 Antoni Pokusinski <[email protected]>…

Silicon Labs Si7210 is an I2C Hall effect magnetic position and temperature sensor. The driver supports the following functionalities:
* reading the temperature measurements
* reading the magnetic field measurements in a single-shot mode
* choosing the magnetic field measurement scale (20 or 200 mT)

Hi Antoni

A few comments inline. Main one is that I 'think' the scale for the temperature is off by 1000. I got a bit lost in the maths so may have that wrong.

Jonathan

Quoted 7 lines
drivers/iio/magnetometer/si7210.c new file +1 -0
new file mode 100644
index 000000000000..3b9b5b9807fd
@@ -0,0 +1,412 @@
+// SPDX-License-Identifier: GPL-2.0

drivers/iio/magnetometer/si7210.c line 11

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+/*
+ * Silicon Labs Si7210 Hall Effect sensor driver
+ *
+ * Copyright (c) 2024 Antoni Pokusinski <[email protected]>
+ *
+ * Datasheet:
+ *  https://www.silabs.com/documents/public/data-sheets/si7210-datasheet.pdf
+ */
+
+#include <linux/module.h>

Order seems a bit random. Probably better to just go alphabetical.

drivers/iio/magnetometer/si7210.c

Quoted 11 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+#include <linux/i2c.h>
+#include <linux/iio/iio.h>
+#include <linux/regmap.h>
+#include <linux/math64.h>
+#include <linux/mutex.h>
 
+struct si7210_data {
+	struct i2c_client *client;
+	struct regmap *regmap;
+	struct mutex fetch_lock;
+	struct mutex otp_lock;

Even though somewhat obvious, each lock needs a comment on what data it is protecting.

For the otp_lock I'm not sure you even needed as it is only used during probe. If that weren't the case, can you safely overlap fetch and otp? Is it worth that distinction, if not is one lock enough?

Quoted 12 lines
drivers/iio/magnetometer/si7210.c new file +12 -0
+	s8 temp_offset;
+	s8 temp_gain;
+	s8 scale_20_a[A_REGS_COUNT];
+	s8 scale_200_a[A_REGS_COUNT];
+	u8 curr_scale;
+};
+
+static const struct iio_chan_spec si7210_channels[] = {
+	{
+		.type = IIO_MAGN,
+		.info_mask_separate = BIT(IIO_CHAN_INFO_RAW) |
+			BIT(IIO_CHAN_INFO_SCALE) | BIT(IIO_CHAN_INFO_OFFSET),

drivers/iio/magnetometer/si7210.c line 145

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+	},
+	{
+		.type = IIO_TEMP,
+		.info_mask_separate = BIT(IIO_CHAN_INFO_PROCESSED),
+	}
+};
+
+static int si7210_fetch_measurement(struct si7210_data *data,
+				    struct iio_chan_spec const *chan,
+				    u8 buf[2])

See below. May be worth treating this as a __be16?
It is described in the datasheet as being made up of most significant and least significant bytes so that seems a logic cleanup.

drivers/iio/magnetometer/si7210.c line 150

Quoted 5 lines
drivers/iio/magnetometer/si7210.c new file +5 -0
+{
+	u8 dspsigsel = chan->type == IIO_MAGN ? 0 : 1;
+	int ret;
+
+	scoped_guard(mutex, &data->fetch_lock) {

As below. guard(mutex) better here to reduce indent a little and indicate the lock is held for whole function.

Quoted 26 lines
drivers/iio/magnetometer/si7210.c new file +26 -0
+		ret = regmap_update_bits(data->regmap, SI7210_REG_DSPSIGSEL,
+					 SI7210_MASK_DSPSIGSEL, dspsigsel);
+		if (ret < 0)
+			return ret;
+
+		ret = regmap_update_bits(data->regmap, SI7210_REG_POWER_CTRL,
+					 SI7210_MASK_ONEBURST | SI7210_MASK_STOP,
+					 SI7210_MASK_ONEBURST & ~SI7210_MASK_STOP);
+		if (ret < 0)
+			return ret;
+
+		/* Read the contents of the registers containing the result: DSPSIGM, DSPSIGL */
+		ret = regmap_bulk_read(data->regmap, SI7210_REG_DSPSIGM, buf, 2);
+		if (ret < 0)
+			return ret;
+	}
+
+	return 0;
+}
+
+static int si7210_read_raw(struct iio_dev *indio_dev,
+			   struct iio_chan_spec const *chan,
+			   int *val, int *val2, long mask)
+{
+	struct si7210_data *data = iio_priv(indio_dev);
+	long long tmp;

drivers/iio/magnetometer/si7210.c line 186

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+	u8 dspsig[2];
+	int ret;
+
+	switch (mask) {
+	case IIO_CHAN_INFO_RAW:
+		ret = si7210_fetch_measurement(data, chan, dspsig);
+		if (ret < 0)
+			return ret;
+
+		*val = ((dspsig[0] & 0x7F) << 8) + dspsig[1];

Very nearly a simple endian get. Probably better to treat it like one anyway. *val = get_unaligned_be16(dpsig) & GENMASK(14, 0)

Quoted 7 lines
drivers/iio/magnetometer/si7210.c new file +7 -0
+		return IIO_VAL_INT;
+	case IIO_CHAN_INFO_SCALE:
+		*val = 0;
+		if (data->curr_scale == 20)
+			*val2 = 1250;
+		else /* data->curr_scale == 200 */
+			*val2 = 12500;

drivers/iio/magnetometer/si7210.c line 203

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+		return IIO_VAL_INT_PLUS_MICRO;
+	case IIO_CHAN_INFO_OFFSET:
+		*val = -16384;
+		return IIO_VAL_INT;
+	case IIO_CHAN_INFO_PROCESSED:
+		ret = si7210_fetch_measurement(data, chan, dspsig);
+		if (ret < 0)
+			return ret;
+
+		tmp = ((dspsig[0] & 0x7F) << 5) + (dspsig[1] >> 3);

This may be appropriate as an endian read and FIELD_GET(). Perhaps not worth it except that the type for the fetch_measurements could then be a __be16 rather than what looks like unrelated u8 pair.

Given the docs have this a most and least significant bytes that seems to make sense to me.

drivers/iio/magnetometer/si7210.c line 206

Quoted 3 lines
drivers/iio/magnetometer/si7210.c new file +3 -0
+		tmp = (div_s64(-383 * tmp * tmp, 100) + (160940 * tmp - 279800000));
+		tmp = (1 + (data->temp_gain >> 11)) * tmp + 62500 * data->temp_offset;
+		tmp -= 732600;

This is form 0.222 * VDD, given you should have a regulator as per the binding feedback you should be able to query that voltage.

drivers/iio/magnetometer/si7210.c line 209

Quoted 3 lines
drivers/iio/magnetometer/si7210.c new file +3 -0
+
+		*val = div_s64_rem(tmp, 1000000, val2);
+

I think this is returning a value in degrees celsius? IIO ABI matches older hwmon on temperatures and is in milicelsius. (Documentation/ABI/testing/sysfs-bus-iio)

Please check other units match the aABI.

Quoted 9 lines
drivers/iio/magnetometer/si7210.c new file +9 -0
+		return IIO_VAL_INT_PLUS_MICRO;
+	default:
+		return -EINVAL;
+	}
+}
+
+static int si7210_set_scale(struct si7210_data *data, unsigned int scale)
+{
+	s8 *a_otp_values;

drivers/iio/magnetometer/si7210.c line 228

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+	int ret;
+
+	if (scale == 20)
+		a_otp_values = data->scale_20_a;
+	else if (scale == 200)
+		a_otp_values = data->scale_200_a;
+	else
+		return -EINVAL;
+
+	scoped_guard(mutex, &data->fetch_lock) {

As below (though this one is a little less clear as it's mid way through the function). I would just used guard()

Quoted 12 lines
drivers/iio/magnetometer/si7210.c new file +12 -0
+		/* Write the registers 0xCA - 0xCC*/
+		ret = regmap_bulk_write(data->regmap, SI7210_REG_A0, a_otp_values, 3);
+		if (ret < 0)
+			return ret;
+
+		/* Write the registers 0xCE - 0xD0*/
+		ret = regmap_bulk_write(data->regmap, SI7210_REG_A3, &a_otp_values[3], 3);
+		if (ret < 0)
+			return ret;
+
+		data->curr_scale = scale;
+	}

drivers/iio/magnetometer/si7210.c line 272

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +9 -0
+
+	return 0;
+}
 
+static int si7210_read_otpreg_val(struct si7210_data *data, unsigned int otpreg, u8 *val)
+{
+	int ret;
+	unsigned int otpdata;
+
+	scoped_guard(mutex, &data->otp_lock) {

As you hold the lock for the whole body, I would just use

	guard(mutex)(&datap->otp_lock);

as then the indent of the rest will be reduced, slightly improving readability.

Quoted 15 lines
drivers/iio/magnetometer/si7210.c new file +15 -0
+		ret = regmap_write(data->regmap, SI7210_REG_OTP_ADDR, otpreg);
+		if (ret < 0)
+			return ret;
+
+		ret = regmap_update_bits(data->regmap, SI7210_REG_OTP_CTRL,
+					 SI7210_MASK_OTP_READ_EN, SI7210_MASK_OTP_READ_EN);
+		if (ret < 0)
+			return ret;
+
+		ret = regmap_read(data->regmap, SI7210_REG_OTP_DATA, &otpdata);
+		if (ret < 0)
+			return ret;
+
+		*val = (u8)otpdata;
+	}

drivers/iio/magnetometer/si7210.c line 297

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+
+	return 0;
+}
+
+static int si7210_device_wake(struct si7210_data *data)
+{
+	/* According to the datasheet, the primary method to wake up a device is
+	 *  to send an empty write. However this is not feasible using current API so we
+	 *  use the other method i.e. read a single byte. The device should respond with 0xFF
+	 */

Comment syntax for IIO would make this
/*
* According to the datasheet, the primary method to wake up a
* device is to send an empty write. However this is not feasible
* using current API so we use the other method i.e. read a single
* byte. The device should respond with 0xFF
*/

drivers/iio/magnetometer/si7210.c line 305

Quoted 8 lines
drivers/iio/magnetometer/si7210.c new file +8 -0
+
+	int ret = 0;
+
+	ret = i2c_smbus_read_byte(data->client);
+	if (ret < 0)
+		return ret;
+
+	if ((u8)ret != 0xFF)

Why is the cast needed?

Quoted 5 lines
drivers/iio/magnetometer/si7210.c new file +5 -0
+		return -EIO;
+
+	return 0;
+}
+

drivers/iio/magnetometer/si7210.c line 320

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+static int si7210_device_init(struct si7210_data *data)
+{
+	int ret;
+	unsigned int i;
+
+	ret = si7210_device_wake(data);
+	if (ret < 0)
+		return ret;
+
+	usleep_range(1000, 1500);

fsleep() preferred. It'll use slightly different range, but the aim of that function is we never need to care what exactly is set and consider if the margin is reasonable or not.

Quoted 34 lines
drivers/iio/magnetometer/si7210.c new file +34 -0
+
+	ret = si7210_read_otpreg_val(data, SI7210_OTPREG_TMP_GAIN, &data->temp_gain);
+	if (ret < 0)
+		return ret;
+	ret = si7210_read_otpreg_val(data, SI7210_OTPREG_TMP_OFF, &data->temp_offset);
+	if (ret < 0)
+		return ret;
+
+	for (i = 0; i < A_REGS_COUNT; i++) {
+		ret = si7210_read_otpreg_val(data, a20_otp_regs[i], &data->scale_20_a[i]);
+		if (ret < 0)
+			return ret;
+	}
+	for (i = 0; i < A_REGS_COUNT; i++) {
+		ret = si7210_read_otpreg_val(data, a200_otp_regs[i], &data->scale_200_a[i]);
+		if (ret < 0)
+			return ret;
+	}
+
+	ret = regmap_update_bits(data->regmap, SI7210_REG_ARAUTOINC,
+				 SI7210_MASK_ARAUTOINC, SI7210_MASK_ARAUTOINC);
+	if (ret < 0)
+		return ret;
+
+	return si7210_set_scale(data, 20);
+}
+
+static const struct iio_info si7210_info = {
+	.read_raw = si7210_read_raw,
+	.write_raw = si7210_write_raw,
+};
+
+static int si7210_probe(struct i2c_client *client)
+{

drivers/iio/magnetometer/si7210.c line 364

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+	struct si7210_data *data;
+	struct iio_dev *indio_dev;
+	int ret;
+
+	indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*data));
+	if (!indio_dev)
+		return -ENOMEM;
+
+	data = iio_priv(indio_dev);
+	i2c_set_clientdata(client, indio_dev);

Is this used? If not don't set it.

Quoted 9 lines
drivers/iio/magnetometer/si7210.c new file +9 -0
+	data->client = client;
+
+	mutex_init(&data->fetch_lock);
+	mutex_init(&data->otp_lock);
+
+	data->regmap = devm_regmap_init_i2c(client, &si7210_regmap_conf);
+	if (IS_ERR(data->regmap))
+		return dev_err_probe(&client->dev, PTR_ERR(data->regmap),
+				     "failed to register regmap\n");

drivers/iio/magnetometer/si7210.c line 383

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+
+	indio_dev->name = dev_name(&client->dev);
+	indio_dev->modes = INDIO_DIRECT_MODE;
+	indio_dev->info = &si7210_info;
+	indio_dev->channels = si7210_channels;
+	indio_dev->num_channels = ARRAY_SIZE(si7210_channels);
+
+	ret = si7210_device_init(data);
+	if (ret)
+		return dev_err_probe(&client->dev, ret, "device initialization failed\n");

Generally we try to keep the line length in IIO to traditional 80 chars unless there is a good readability reason to do otherwise. Here I'd wrap before the message.

drivers/iio/magnetometer/si7210.c line 389

Quoted 6 lines
drivers/iio/magnetometer/si7210.c new file +6 -0
+
+	return devm_iio_device_register(&client->dev, indio_dev);
+}
+
+static const struct i2c_device_id si7210_id[] = {
+	{ "si7210", 0 },

Trivial: No real point in setting the 0 explicitly.

Quoted 7 lines
drivers/iio/magnetometer/si7210.c new file +7 -0
+	{ }
+};
+MODULE_DEVICE_TABLE(i2c, si7210_id);
+
+static const struct of_device_id si7210_dt_ids[] = {
+	{ .compatible = "silabs,si7210" },
+	{ }

drivers/iio/magnetometer/si7210.c line 406

Quoted 10 lines
drivers/iio/magnetometer/si7210.c new file +10 -0
+};
+MODULE_DEVICE_TABLE(of, si7210_dt_ids);
+
+static struct i2c_driver si7210_driver = {
+	.driver = {
+		.name = "si7210",
+		.of_match_table = si7210_dt_ids,
+	},
+	.probe		= si7210_probe,
+	.id_table	= si7210_id,

Totally trivial but I'd not bother with tab alignment at all rather than mixing using it and not here.
.probe = si7120_probe, etc is fine and avoids mess of realigning in future
if something longer named turns up.

Quoted 6 lines
drivers/iio/magnetometer/si7210.c new file +6 -0
+};
+
+module_i2c_driver(si7210_driver);
+MODULE_AUTHOR("Antoni Pokusinski <[email protected]>");
+MODULE_DESCRIPTION("Silicon Labs Si7210 Hall Effect sensor I2C driver");
+MODULE_LICENSE("Dual BSD/GPL");