riscv: dts: allwinner: d1: Add CPU thermal sensor and zone
Subsystems (3)
PATCH v2 1/1 riscv: dts: allwinner: d1: Add CPU thermal sensor and zone
From: Alex Studer <[email protected]>
The sun20i THS (built in CPU thermal sensor) is supported in code, but was never added to the device tree. So, add it to the device tree, along with a thermal zone for the CPU.
Changes since v1:
- Move include before defines in sun20i-d1s.dtsi
- Fix register size for thermal-sensor@2009400
- Move thermal-sensor@2009400 in SoC to match register address sorting
- Add thermal-zone for sun8i-t113s.dtsi and fix missing cooling-cells
--- arch/arm/boot/dts/allwinner/sun8i-t113s.dtsi | 33 +++++++++++++++++++ arch/riscv/boot/dts/allwinner/sun20i-d1s.dtsi | 31 +++++++++++++++++ .../boot/dts/allwinner/sunxi-d1s-t113.dtsi | 16 +++++++++ 3 files changed, 80 insertions(+)
arch/arm/boot/dts/allwinner/sun8i-t113s.dtsi +33 -0
@@ -4,6 +4,7 @@ #define SOC_PERIPHERAL_IRQ(nr) GIC_SPI nr #include <dt-bindings/interrupt-controller/arm-gic.h> +#include <dt-bindings/thermal/thermal.h> #include <riscv/allwinner/sunxi-d1s-t113.dtsi> #include <riscv/allwinner/sunxi-d1-t113.dtsi>
@@ -20,6 +21,7 @@ cpu0: cpu@0 { reg = <0>; clocks = <&ccu CLK_CPUX>; clock-names = "cpu"; + #cooling-cells = <2>; }; cpu1: cpu@1 {
@@ -28,6 +30,7 @@ cpu1: cpu@1 { reg = <1>; clocks = <&ccu CLK_CPUX>; clock-names = "cpu"; + #cooling-cells = <2>; }; };
@@ -56,4 +59,34 @@ pmu { <GIC_SPI 173 IRQ_TYPE_LEVEL_HIGH>; interrupt-affinity = <&cpu0>, <&cpu1>; }; + + thermal-zones { + cpu-thermal { + polling-delay-passive = <0>; + polling-delay = <0>; + thermal-sensors = <&ths>; + + cooling-maps { + map0 { + trip = <&cpu_alert>; + cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, + <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + }; + }; + + trips { + cpu_alert: cpu-alert { + temperature = <85000>; + hysteresis = <2000>; + type = "passive"; + }; + + cpu-crit { + temperature = <100000>; + hysteresis = <0>; + type = "critical"; + }; + }; + }; + }; };
arch/riscv/boot/dts/allwinner/sun20i-d1s.dtsi +31 -0
@@ -1,6 +1,8 @@ // SPDX-License-Identifier: (GPL-2.0+ OR MIT) // Copyright (C) 2021-2022 Samuel Holland <[email protected]> +#include <dt-bindings/thermal/thermal.h> + #define SOC_PERIPHERAL_IRQ(nr) (nr + 16) #include "sunxi-d1s-t113.dtsi"
@@ -115,4 +117,33 @@ pmu { <0x00000000 0x0000000e 0xffffffff 0xffffffff 0x00010000>, <0x00000000 0x0000000f 0xffffffff 0xffffffff 0x00020000>; }; + + thermal-zones { + cpu-thermal { + polling-delay-passive = <0>; + polling-delay = <0>; + thermal-sensors = <&ths>; + + cooling-maps { + map0 { + trip = <&cpu_alert>; + cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + }; + }; + + trips { + cpu_alert: cpu-alert { + temperature = <85000>; + hysteresis = <2000>; + type = "passive"; + }; + + cpu-crit { + temperature = <100000>; + hysteresis = <0>; + type = "critical"; + }; + }; + }; + }; };
arch/riscv/boot/dts/allwinner/sunxi-d1s-t113.dtsi +16 -0
@@ -214,6 +214,18 @@ gpadc: adc@2009000 { #io-channel-cells = <1>; }; + ths: thermal-sensor@2009400 { + compatible = "allwinner,sun20i-d1-ths"; + reg = <0x2009400 0x400>; + interrupts = <SOC_PERIPHERAL_IRQ(58) IRQ_TYPE_LEVEL_HIGH>; + clocks = <&ccu CLK_BUS_THS>; + clock-names = "bus"; + resets = <&ccu RST_BUS_THS>; + nvmem-cells = <&ths_calibration>; + nvmem-cell-names = "calibration"; + #thermal-sensor-cells = <0>; + }; + dmic: dmic@2031000 { compatible = "allwinner,sun20i-d1-dmic", "allwinner,sun50i-h6-dmic";
@@ -474,6 +486,10 @@ sid: efuse@3006000 { reg = <0x3006000 0x1000>; #address-cells = <1>; #size-cells = <1>; + + ths_calibration: thermal-sensor-calibration@14 { + reg = <0x14 0x8>; + }; }; crypto: crypto@3040000 {
Signature · 1 line
2.47.3
Chen-Yu Tsai
maintainerQuoted 6 lines · Lukas Schmid
The sun20i THS (built in CPU thermal sensor) is supported in code, but was never added to the device tree. So, add it to the device tree, along with a thermal zone for the CPU.
Signed-off-by Alex Studer <[email protected]>
Quoted 7 lines
Changes since v1:
- Move include before defines insun20i-d1s.dtsi
- Fix register size for thermal-sensor@2009400
- Move thermal-sensor@2009400 in SoC to match register address sorting
- Add thermal-zone forsun8i-t113s.dtsiand fix missing cooling-cells[...]
Applied to sunxi/dt-for-6.20 in local tree, thanks!
[1/1] riscv: dts: allwinner: d1: Add CPU thermal sensor and zone
commit: f36e738549d483878ebf4cc9826c46d9dc4aa496
Best regards,
Signature · 1 line
Chen-Yu Tsai <[email protected]>