CVE-2025-71272, CVE-2026-43317: backport fix series
cover CVE-2025-71272, CVE-2026-43317: backport fix series
Hi,
Please consider this backport series for CVE-2025-71272, CVE-2026-43317 to 6.6.y.
Apply the patches in this order:
1. most: core: fix resource leak in most_register_interface error paths (fix)
2. most: core: fix leak on early registration failure (fix)
Patch 1 initializes the interface device before ID allocation and releases the device, ID and private storage on registration failures.
Patch 2 moves callback and channel-count validation after device initialization so those early failures also release the device. The code changes in both patches are identical to upstream.
The complete fix is already present in 6.12.y, 6.18.y and 7.2.y.
Build-tested only as part of a cumulative 6.6.y series: x86_64 objects (allmodconfig, CONFIG_WERROR=y); no runtime testing.
An LLM assisted with preparing these backports.
Thanks,
Artem Dinaburg
PATCH 1/2 most: core: fix resource leak in most_register_interface error paths
From: Navaneeth K <[email protected]>
[ Upstream commit 1f4c9d8a1021281750c6cda126d6f8a40cc24e71 ]
The function most_register_interface() did not correctly release resources if it failed early (before registering the device). In these cases, it returned an error code immediately, leaking the memory allocated for the interface.
Fix this by initializing the device early via device_initialize() and calling put_device() on all error paths.
The most_register_interface() is expected to call put_device() on error which frees the resources allocated in the caller. The put_device() either calls release_mdev() or dim2_release(), depending on the caller.
Switch to using device_add() instead of device_register() to handle the split initialization.
---
Hi,
Please consider this backport of the fix for CVE-2025-71272 to 6.6.y.
The code changes are identical to upstream.
The complete fix is already present in 6.12.y, 6.18.y and 7.2.y.
Build-tested only as part of a cumulative 6.6.y series: x86_64 objects (allmodconfig, CONFIG_WERROR=y); no runtime testing.
Thanks,
Artem Dinaburg
drivers/most/core.c | 6 +++++- 1 file changed, 5 insertions(+), 1 deletion(-)
drivers/most/core.c +5 -1
@@ -1286,15 +1286,19 @@ int most_register_interface(struct most_interface *iface) !iface->poison_channel || (iface->num_channels > MAX_CHANNELS))return -EINVAL ; +device_initialize (iface->dev); + id =ida_simple_get (&mdev_id,0 ,0 ,GFP_KERNEL );if (id <0 ) {dev_err (iface->dev,"Failed to allocate device ID\n" ); +put_device (iface->dev);return id; } iface->p =kzalloc (sizeof (*iface->p),GFP_KERNEL );if (!iface->p) {ida_simple_remove (&mdev_id, id); +put_device (iface->dev);return -ENOMEM ; }
@@ -1304,7 +1308,7 @@ int most_register_interface(struct most_interface *iface) iface->dev->bus = &mostbus; iface->dev->groups = interface_attr_groups;dev_set_drvdata (iface->dev, iface); -if (device_register (iface->dev)) { +if (device_add (iface->dev)) {dev_err (iface->dev,"Failed to register interface device\n" );kfree (iface->p);put_device (iface->dev);
PATCH 2/2 most: core: fix leak on early registration failure
In reply to Artem DinaburgFrom: Johan Hovold <[email protected]>
[ Upstream commit 2c198c272f9c9213b0fdf6b4a879f445c574f416 ]
A recent commit fixed a resource leak on early registration failures but for some reason left out the first error path which still leaks the resources associated with the interface.
Fix up also the first error path so that the interface is always released on errors.
---
Hi,
Please consider this backport of the fix for CVE-2026-43317 to 6.6.y.
The code changes are identical to upstream.
The complete fix is already present in 6.12.y, 6.18.y and 7.2.y.
Build-tested only as part of a cumulative 6.6.y series: x86_64 objects (allmodconfig, CONFIG_WERROR=y); no runtime testing.
Thanks,
Artem Dinaburg
drivers/most/core.c | 9 +++++++-- 1 file changed, 7 insertions(+), 2 deletions(-)
drivers/most/core.c +7 -2
@@ -1282,12 +1282,17 @@ int most_register_interface(struct most_interface *iface)int id;struct most_channel *c; -if (!iface || !iface->enqueue || !iface->configure || - !iface->poison_channel || (iface->num_channels >MAX_CHANNELS )) +if (!iface)return -EINVAL ;device_initialize (iface->dev); +if (!iface->enqueue || !iface->configure || !iface->poison_channel || + (iface->num_channels >MAX_CHANNELS )) { +put_device (iface->dev); +return -EINVAL ; + } + id =ida_simple_get (&mdev_id,0 ,0 ,GFP_KERNEL );if (id <0 ) {dev_err (iface->dev,"Failed to allocate device ID\n" );
Quoted 2 lines
Please consider this backport series for CVE-2025-71272, CVE-2026-43317 to 6.6.y.
Queued the series for 6.6, thanks.
Signature · 2 lines
Thanks, Sasha