powerpc: mgcoge, mgsuvd, kmeter1: dont print errormsg if second IVM Block lacks..
PATCH 26/31 powerpc: mgcoge, mgsuvd, kmeter1: dont print errormsg if second IVM Block lacks..
The second IVM inventory block for the keymile boards is optional only, so dont print an error message, if this block dont exists.
Signed-off-by Heiko Schocher <[email protected]>
--- board/keymile/common/common.c | 7 ++++--- 1 files changed, 4 insertions(+), 3 deletions(-)
board/keymile/common/common.c +4 -3
@@ -204,8 +204,9 @@ static int ivm_check_crc (unsigned char *buf, int block) crceeprom = (buf[CONFIG_SYS_IVM_EEPROM_PAGE_LEN -1 ] + \ buf[CONFIG_SYS_IVM_EEPROM_PAGE_LEN -2 ] *256 );if (crc != crceeprom) { -printf ("Error CRC Block: %d EEprom: calculated: %lx EEprom: %lx\n" , - block, crc, crceeprom); +if (block ==0 ) +printf ("Error CRC Block: %d EEprom: calculated: \ +%lx EEprom: %lx\n" , block, crc, crceeprom);return -1 ; }return 0 ;
@@ -288,7 +289,7 @@ int ivm_analyze_eeprom (unsigned char *buf, int len) GET_STRING("IVM_CustomerProductID", IVM_POS_CUSTOMER_PROD_ID, 32)if (ivm_check_crc (&buf[CONFIG_SYS_IVM_EEPROM_PAGE_LEN *2 ],2 ) !=0 ) -return -2 ; +return 0 ;ivm_analyze_block2 (&buf[CONFIG_SYS_IVM_EEPROM_PAGE_LEN *2 ],CONFIG_SYS_IVM_EEPROM_PAGE_LEN );return 0 ;
Signature · 5 lines
1.6.0.6 -- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
PATCH 26/31 powerpc: mgcoge, mgsuvd, kmeter1: dont print errormsg if second IVM Block lacks..
Dear Heiko Schocher,
Quoted 2 lines · In message <[email protected]> you wrote:
The second IVM inventory block for the keymile boards is optional only, so dont print an error message, if this block dont exists.
PLEASE provide somewhat usable commit messages.
Keep in mind that the Subject line is used as summary for the commit, and that it must not exceed some 70 characters.
Event though you use a very long subject it still makes no sense.
Please fix.
Best regards,
Wolfgang Denk
Signature · 4 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de Premature optimization is the root of all evil. -- D.E. Knuth