Skip to contentSkip to conversation

PL310 cache initialization/fixup for BCM63138

DISCUSSION Florian Fainelli 2 participants 4 messages Aug 13, 2014

lore
Share & tools
lore
#0 lore raw

Hi Russell, Arnd,

The PL310 cache present on BCM63138 comes up with wrong values out of reset in particular, I need to at least override the way-size to be 32KiB otherwise.

Right now, I am overriding the auxiliary control register by supplying a non 0xffffffff aux_ctrl_mask to l2x0_of_init().

Should I rather use a separate compatible string for it and perform the "fixup" in a separate of_parse() callback, or in a separate fixup() callback?

Or is it recommended to keep overriding the aux_ctrl_mask as part of the call to l2x0_of_init()?

Thanks!
--
Florian

#1 lore raw
Quoted 9 lines · Florian Fainelli

Hi Russell, Arnd,

The PL310 cache present on BCM63138 comes up with wrong values out of reset in particular, I need to at least override the way-size to be 32KiB otherwise.

Right now, I am overriding the auxiliary control register by supplying a non 0xffffffff aux_ctrl_mask to l2x0_of_init().

Quoted 6 lines

Should I rather use a separate compatible string for it and perform the "fixup" in a separate of_parse() callback, or in a separate fixup() callback?

Or is it recommended to keep overriding the aux_ctrl_mask as part of the call to l2x0_of_init()?

The correct answer is to research how to specify cache attributes in DT, and create an appropriate set of properties described by that, and have the l2x0 OF init code parse those, and create the appropriate aux control register values from those.

I forget exactly what they are, but I do know that there is a standardised set of DT properties to describe the geometry of caches - I came across them about six months back when I worked on the L2 code.

Signature · 2 lines
FTTC broadband for 0.8mile line: currently at 9.5Mbps down 400kbps up
according to speedtest.net.
#2 lore raw
Quoted 17 lines · Russell King - ARM Linux
Quoted 9 lines · Florian Fainelli

Hi Russell, Arnd,

The PL310 cache present on BCM63138 comes up with wrong values out of reset in particular, I need to at least override the way-size to be 32KiB otherwise.

Right now, I am overriding the auxiliary control register by supplying a non 0xffffffff aux_ctrl_mask to l2x0_of_init().

Quoted 6 lines

Should I rather use a separate compatible string for it and perform the "fixup" in a separate of_parse() callback, or in a separate fixup() callback?

Or is it recommended to keep overriding the aux_ctrl_mask as part of the call to l2x0_of_init()?

Quoted 8 lines

The correct answer is to research how to specify cache attributes in DT, and create an appropriate set of properties described by that, and have the l2x0 OF init code parse those, and create the appropriate aux control register values from those.

I forget exactly what they are, but I do know that there is a standardised set of DT properties to describe the geometry of caches - I came across them about six months back when I worked on the L2 code.

Alright, I will take a stab at using the ePAPR cache properties.

How about PL310 specific properties such as instruction prefetc and non-secure access, would boolean properties work for these?

Thanks!
--
Florian

#3 lore raw
Quoted 6 lines · Florian Fainelli
Quoted 5 lines · Russell King - ARM Linux

The correct answer is to research how to specify cache attributes in DT, and create an appropriate set of properties described by that, and have the l2x0 OF init code parse those, and create the appropriate aux control register values from those.

Quoted 8 lines
Quoted 3 lines

I forget exactly what they are, but I do know that there is a standardised set of DT properties to describe the geometry of caches - I came across them about six months back when I worked on the L2 code.

Alright, I will take a stab at using the ePAPR cache properties.

How about PL310 specific properties such as instruction prefetc and non-secure access, would boolean properties work for these?

We always enable non-secure access. If we're running in secure mode, enabling non-secure access will be accepted by the hardware, and as we run in secure mode, has no effect. If we're running in non-secure mode, then we need to ask the firmware to enable non-secure access to things like the unlock registers, and eventually the interrupt registers anyway.

So it makes no sense for that to be a property.

For instruction prefetch, does it make sense for it to be in DT at all - is there a reason not to enable it as a matter of course?

Signature · 2 lines
FTTC broadband for 0.8mile line: currently at 9.5Mbps down 400kbps up
according to speedtest.net.