Support pli1209bc Digital Supervisor
Subsystems (3)
v3 cover Support pli1209bc Digital Supervisor
Hi,
This patch set adds support for PLI1209BC Digital Supervisor from Vicor Corporation. It replaces the previous submitted driver "bcm6123" [1], since there are multiple digital supervisors, which uses BCMs in different configurations [2].
Change in v3:
- prevent potential over- or underflow of PMBUS_READ_POUT
Changes in v2:
- Multiply PMBUS_READ_POUT with 10 (R=1)
instead of dividing PMBUS_READ_PIN by 10.
- Set all pmbus formats to direct.
- Comment reason why page 0 is redundant.
- Import pmbus namespace.
[1]: https://www.spinics.net/lists/linux-hwmon/msg14097.html
[2]: https://www.spinics.net/lists/linux-hwmon/msg14123.html
Marcello Sylvester Bauer (4):
dt-bindings: vendor-prefixes: add Vicor Corporation dt-bindings:trivial-devices: Add pli1209bc
pmbus: Add support for pli1209bc
pmbus (pli1209bc): Add regulator support
.../devicetree/bindings/trivial-devices.yaml | 2 + .../devicetree/bindings/vendor-prefixes.yaml | 2 + Documentation/hwmon/pli1209bc.rst | 73 +++++++++ drivers/hwmon/pmbus/Kconfig | 16 ++ drivers/hwmon/pmbus/Makefile | 1 + drivers/hwmon/pmbus/pli1209bc.c | 146 ++++++++++++++++++ 6 files changed, 240 insertions(+) create mode 100644 Documentation/hwmon/pli1209bc.rst create mode 100644 drivers/hwmon/pmbus/pli1209bc.c
Signature · 1 line
2.34.1
PATCH v3 1/4 dt-bindings: vendor-prefixes: add Vicor Corporation
Add vendor prefix for Vicor Corporation.
--- Documentation/devicetree/bindings/vendor-prefixes.yaml | 2 ++ 1 file changed, 2 insertions(+)
Documentation/devicetree/bindings/vendor-prefixes.yaml +2 -0
@@ -1298,6 +1298,8 @@ patternProperties: description: Vertexcom Technologies, Inc. "^via,.*": description: VIA Technologies, Inc. + "^vicor,.*": + description: Vicor Corporation "^videostrong,.*": description: Videostrong Technology Co., Ltd. "^virtio,.*":
Signature · 1 line
2.34.1
PATCH v3 2/4 dt-bindings:trivial-devices: Add pli1209bc
In reply to Marcello Sylvester BauerAdd trivial device entry for PLI1209BC Digital Supervisor from Vicor Corporation.
--- Documentation/devicetree/bindings/trivial-devices.yaml | 2 ++ 1 file changed, 2 insertions(+)
Documentation/devicetree/bindings/trivial-devices.yaml +2 -0
@@ -354,6 +354,8 @@ properties: - ti,tps544c25 # Winbond/Nuvoton H/W Monitor - winbond,w83793 + # Vicor Corporation Digital Supervisor + - vicor,pli1209bc # i2c trusted platform module (TPM) - winbond,wpct301
Signature · 1 line
2.34.1
PATCH v3 3/4 pmbus: Add support for pli1209bc
In reply to Marcello Sylvester BauerPLI1209BC is a Digital Supervisor from Vicor Corporation.
--- Documentation/hwmon/pli1209bc.rst | 73 +++++++++++++++++++ drivers/hwmon/pmbus/Kconfig | 9 +++ drivers/hwmon/pmbus/Makefile | 1 + drivers/hwmon/pmbus/pli1209bc.c | 115 ++++++++++++++++++++++++++++++ 4 files changed, 198 insertions(+) create mode 100644 Documentation/hwmon/pli1209bc.rst create mode 100644 drivers/hwmon/pmbus/pli1209bc.c
Documentation/hwmon/pli1209bc.rst new file +73 -0
@@ -0,0 +1,73 @@ +Kernel driver pli1209bc +======================= + +Supported chips: + + * Digital Supervisor PLI1209BC + + Prefix: 'pli1209bc' + + Addresses scanned: 0x50 - 0x5F + + Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf + +Authors: + - Marcello Sylvester Bauer <[email protected]> + +Description +----------- + +The Vicor PLI1209BC is an isolated digital power system supervisor thatprovides +a communication interface between a host processor and one Bus Converter Module +(BCM). The PLI communicates with a system controller via a PMBus compatible +interface over an isolated UART interface. Through the PLI, the host processor +can configure, set protection limits, and monitor the BCM. + +Sysfs entries +------------- + +======================= ======================================================== +in1_label "vin2" +in1_input Input voltage. +in1_rated_min Minimum rated input voltage. +in1_rated_max Maximum rated input voltage. +in1_max Maximum input voltage. +in1_max_alarm Input voltage high alarm. +in1_crit Critical input voltage. +in1_crit_alarm Input voltage critical alarm. + +in2_label "vout2" +in2_input Output voltage. +in2_rated_min Minimum rated output voltage. +in2_rated_max Maximum rated output voltage. +in2_alarm Output voltage alarm + +curr1_label "iin2" +curr1_input Input current. +curr1_max Maximum input current. +curr1_max_alarm Maximum input current high alarm. +curr1_crit Critical input current. +curr1_crit_alarm Input current critical alarm. + +curr2_label "iout2" +curr2_input Output current. +curr2_crit Critical output current. +curr2_crit_alarm Output current critical alarm. +curr2_max Maximum output current. +curr2_max_alarm Output current high alarm. + +power1_label "pin2" +power1_input Input power. +power1_alarm Input power alarm. + +power2_label "pout2" +power2_input Output power. +power2_rated_max Maximum rated output power. + +temp1_input Die temperature. +temp1_alarm Die temperature alarm. +temp1_max Maximum die temperature. +temp1_max_alarm Die temperature high alarm. +temp1_crit Critical die temperature. +temp1_crit_alarm Die temperature critical alarm. +======================= ========================================================
drivers/hwmon/pmbus/Kconfig +9 -0
@@ -310,6 +310,15 @@ config SENSORS_PIM4328 This driver can also be built as a module. If so, the module will be called pim4328. +config SENSORS_PLI1209BC + tristate "Vicor PLI1209BC" + help + If you say yes here you get hardware monitoring support for Vicor + PLI1209BC Digital Supervisor. + + This driver can also be built as a module. If so, the module will + be called pli1209bc. + config SENSORS_PM6764TR tristate "ST PM6764TR" help
drivers/hwmon/pmbus/Makefile +1 -0
@@ -34,6 +34,7 @@ obj-$(CONFIG_SENSORS_MP2888) += mp2888.o obj-$(CONFIG_SENSORS_MP2975) += mp2975.o obj-$(CONFIG_SENSORS_MP5023) += mp5023.o obj-$(CONFIG_SENSORS_PM6764TR) += pm6764tr.o +obj-$(CONFIG_SENSORS_PLI1209BC) += pli1209bc.o obj-$(CONFIG_SENSORS_PXE1610) += pxe1610.o obj-$(CONFIG_SENSORS_Q54SJ108A2) += q54sj108a2.o obj-$(CONFIG_SENSORS_STPDDC60) += stpddc60.o
drivers/hwmon/pmbus/pli1209bc.c new file +115 -0
115 lines not on this page · raw message
Signature · 1 line
2.34.1
Guenter Roeck
maintainerRe: [PATCH v3 3/4] pmbus: Add support for pli1209bc
Quoted 3 lines · Marcello Sylvester Bauer
PLI1209BC is a Digital Supervisor from Vicor Corporation.
Signed-off-by Marcello Sylvester Bauer <[email protected]>
checkpatch says:
WARNING: Missing or malformed SPDX-License-Identifier tag in line 1 #82: FILE: Documentation/hwmon/pli1209bc.rst:1:
+Kernel driver pli1209bc
I can not accept the patch without license identifier.
Quoted 2 lines
--- Documentation/hwmon/pli1209bc.rst | 73 +++++++++++++++++++
This needs to be added to Documentation/hwmon/index.rst.
Quoted 23 lines
drivers/hwmon/pmbus/Kconfig | 9 +++ drivers/hwmon/pmbus/Makefile | 1 + drivers/hwmon/pmbus/pli1209bc.c | 115 ++++++++++++++++++++++++++++++ 4 files changed, 198 insertions(+) create mode 100644 Documentation/hwmon/pli1209bc.rst create mode 100644 drivers/hwmon/pmbus/pli1209bc.cDocumentation/hwmon/pli1209bc.rst new file +10
-0@@ -0,0 +1,73 @@ +Kernel driver pli1209bc +======================= + +Supported chips: + + * Digital Supervisor PLI1209BC + + Prefix: 'pli1209bc' + + Addresses scanned: 0x50 - 0x5F
Documentation/hwmon/pli1209bc.rst line 20
Quoted 10 lines
Documentation/hwmon/pli1209bc.rst new file +10
-0+ + Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf + +Authors: + - Marcello Sylvester Bauer <[email protected]> + +Description +----------- + +The Vicor PLI1209BC is an isolated digital power system supervisor thatprovides
that provides
Quoted 78 lines
Documentation/hwmon/pli1209bc.rst new file +53
-0+a communication interface between a host processor and one Bus Converter Module +(BCM). The PLI communicates with a system controller via a PMBus compatible +interface over an isolated UART interface. Through the PLI, the host processor +can configure, set protection limits, and monitor the BCM. + +Sysfs entries +------------- + +======================= ======================================================== +in1_label "vin2" +in1_input Input voltage. +in1_rated_min Minimum rated input voltage. +in1_rated_max Maximum rated input voltage. +in1_max Maximum input voltage. +in1_max_alarm Input voltage high alarm. +in1_crit Critical input voltage. +in1_crit_alarm Input voltage critical alarm. + +in2_label "vout2" +in2_input Output voltage. +in2_rated_min Minimum rated output voltage. +in2_rated_max Maximum rated output voltage. +in2_alarm Output voltage alarm + +curr1_label "iin2" +curr1_input Input current. +curr1_max Maximum input current. +curr1_max_alarm Maximum input current high alarm. +curr1_crit Critical input current. +curr1_crit_alarm Input current critical alarm. + +curr2_label "iout2" +curr2_input Output current. +curr2_crit Critical output current. +curr2_crit_alarm Output current critical alarm. +curr2_max Maximum output current. +curr2_max_alarm Output current high alarm. + +power1_label "pin2" +power1_input Input power. +power1_alarm Input power alarm. + +power2_label "pout2" +power2_input Output power. +power2_rated_max Maximum rated output power. + +temp1_input Die temperature. +temp1_alarm Die temperature alarm. +temp1_max Maximum die temperature. +temp1_max_alarm Die temperature high alarm. +temp1_crit Critical die temperature. +temp1_crit_alarm Die temperature critical alarm. +======================= ========================================================drivers/hwmon/pmbus/Kconfig +9
-0@@ -310,6 +310,15 @@ config SENSORS_PIM4328 This driver can also be built as a module. If so, the module will be called pim4328. +config SENSORS_PLI1209BC + tristate "Vicor PLI1209BC" + help + If you say yes here you get hardware monitoring support for Vicor + PLI1209BC Digital Supervisor. + + This driver can also be built as a module. If so, the module will + be called pli1209bc. + config SENSORS_PM6764TR tristate "ST PM6764TR" helpdrivers/hwmon/pmbus/Makefile +0
-0
drivers/hwmon/pmbus/Makefile obj-$(CONFIG_SENSORS_MP2888) += mp2888.o · line 37
Quoted 4 lines
drivers/hwmon/pmbus/Makefile +1
-0@@ -34,6 +34,7 @@ obj-$(CONFIG_SENSORS_MP2888) += mp2888.o obj-$(CONFIG_SENSORS_MP2975) += mp2975.o obj-$(CONFIG_SENSORS_MP5023) += mp5023.o obj-$(CONFIG_SENSORS_PM6764TR) += pm6764tr.o +obj-$(CONFIG_SENSORS_PLI1209BC) += pli1209bc.o
Alphabetic order please.
Quoted 124 lines
drivers/hwmon/pmbus/Makefile +0
-0obj-$(CONFIG_SENSORS_PXE1610) += pxe1610.o obj-$(CONFIG_SENSORS_Q54SJ108A2) += q54sj108a2.o obj-$(CONFIG_SENSORS_STPDDC60) += stpddc60.odrivers/hwmon/pmbus/pli1209bc.c new file +115
-0@@ -0,0 +1,115 @@ +// SPDX-License-Identifier: GPL-2.0+ +/* +* Hardware monitoring driver for Vicor PLI1209BC Digital Supervisor +* +* Copyright (c) 2022 9elements GmbH +*/ + +#include <linux/i2c.h> +#include <linux/module.h> +#include <linux/pmbus.h> +#include "pmbus.h" + +/* +* The capability command is only supported at page 0. Probing the device while +* the page register is set to 1 will falsely enable PEC support. Disable +* capability probing accordingly, since the PLI1209BC does not have any +* additional capabilities. +*/ +static struct pmbus_platform_data pli1209bc_plat_data = { + .flags =PMBUS_NO_CAPABILITY , +}; + +static int pli1209bc_read_word_data (struct i2c_client *client,int page, +int phase,int reg) +{ +int data; + +switch (reg) { +/* PMBUS_READ_POUT uses a direct format with R=0 */ +case PMBUS_READ_POUT : + data =pmbus_read_word_data (client, page, phase, reg); +if (data <0 ) +return data; + data =sign_extend32 (data,15 ) *10 ; +return clamp_val (data,-32768 ,32767 ) &0xffff ; +default : +return -ENODATA ; + } +} + +static struct pmbus_driver_info pli1209bc_info = { + .pages =2 , + .format[PSC_VOLTAGE_IN ] = direct, + .format[PSC_VOLTAGE_OUT ] = direct, + .format[PSC_CURRENT_IN ] = direct, + .format[PSC_CURRENT_OUT ] = direct, + .format[PSC_POWER ] = direct, + .format[PSC_TEMPERATURE ] = direct, + .m[PSC_VOLTAGE_IN ] =1 , + .b[PSC_VOLTAGE_IN ] =0 , + .R[PSC_VOLTAGE_IN ] =1 , + .m[PSC_VOLTAGE_OUT ] =1 , + .b[PSC_VOLTAGE_OUT ] =0 , + .R[PSC_VOLTAGE_OUT ] =1 , + .m[PSC_CURRENT_IN ] =1 , + .b[PSC_CURRENT_IN ] =0 , + .R[PSC_CURRENT_IN ] =3 , + .m[PSC_CURRENT_OUT ] =1 , + .b[PSC_CURRENT_OUT ] =0 , + .R[PSC_CURRENT_OUT ] =2 , + .m[PSC_POWER ] =1 , + .b[PSC_POWER ] =0 , + .R[PSC_POWER ] =1 , + .m[PSC_TEMPERATURE ] =1 , + .b[PSC_TEMPERATURE ] =0 , + .R[PSC_TEMPERATURE ] =0 , +/* +* Page 0 sums up all attributes except voltage readings. +* The pli1209 digital supervisor only contains a single BCM, making +* page 0 redundant. +*/ + .func[1 ] =PMBUS_HAVE_VIN |PMBUS_HAVE_VOUT + |PMBUS_HAVE_IIN |PMBUS_HAVE_IOUT + |PMBUS_HAVE_PIN |PMBUS_HAVE_POUT + |PMBUS_HAVE_TEMP |PMBUS_HAVE_STATUS_TEMP + |PMBUS_HAVE_STATUS_IOUT |PMBUS_HAVE_STATUS_INPUT , + .read_word_data = pli1209bc_read_word_data, +}; + +static int pli1209bc_probe (struct i2c_client *client) +{ + client->dev.platform_data = &pli1209bc_plat_data; +return pmbus_do_probe (client, &pli1209bc_info); +} + +static const struct i2c_device_id pli1209bc_id[] = { + {"pli1209bc" ,0 }, + {} +}; + +MODULE_DEVICE_TABLE (i2c, pli1209bc_id); + +#ifdef CONFIG_OF +static const struct of_device_id pli1209bc_of_match[] = { + { .compatible ="vicor,pli1209bc" }, + { }, +}; +MODULE_DEVICE_TABLE (of, pli1209bc_of_match); +#endif + +static struct i2c_driver pli1209bc_driver = { + .driver = { + .name ="pli1209bc" , + .of_match_table =of_match_ptr (pli1209bc_of_match), + }, + .probe_new = pli1209bc_probe, + .id_table = pli1209bc_id, +}; + +module_i2c_driver (pli1209bc_driver); + +MODULE_AUTHOR ("Marcello Sylvester Bauer <[email protected]>" ); +MODULE_DESCRIPTION ("PMBus driver for Vicor PLI1209BC" ); +MODULE_LICENSE ("GPL" ); +MODULE_IMPORT_NS (PMBUS );
Re: [PATCH v3 3/4] pmbus: Add support for pli1209bc
Quoted 6 lines · Guenter Roeck
Quoted 3 lines · Marcello Sylvester Bauer
PLI1209BC is a Digital Supervisor from Vicor Corporation.
Signed-off-by Marcello Sylvester Bauer <[email protected]>
Quoted 7 lines
checkpatch says:
WARNING: Missing or malformed SPDX-License-Identifier tag in line 1 #82: FILE:
Documentation/hwmon/pli1209bc.rst:1:
+Kernel driver pli1209bcI can not accept the patch without license identifier.
oh, sure. I thought it is still optional for documentation entries.
Quoted 37 lines
Quoted 3 lines
---
Documentation/hwmon/pli1209bc.rst | 73 +++++++++++++++++++This needs to be added to
Documentation/hwmon/index.rst.Quoted 31 lines
drivers/hwmon/pmbus/Kconfig | 9 +++
drivers/hwmon/pmbus/Makefile | 1 +
drivers/hwmon/pmbus/pli1209bc.c | 115
++++++++++++++++++++++++++++++4 files changed, 198 insertions(+)create mode 100644
Documentation/hwmon/pli1209bc.rstcreate mode 100644drivers/hwmon/pmbus/pli1209bc.cDocumentation/hwmon/pli1209bc.rst new file +12
-0@@ -0,0 +1,73 @@ +Kernel driver pli1209bc +======================= + +Supported chips: + + * Digital Supervisor PLI1209BC + + Prefix: 'pli1209bc' + + Addresses scanned: 0x50 - 0x5F + + Datasheet:https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf
Documentation/hwmon/pli1209bc.rst new file +3
-0+ +Authors: + - Marcello Sylvester Bauer <[email protected]>
Quoted 8 lines
Quoted 6 lines
Documentation/hwmon/pli1209bc.rst new file +5
-0+ +Description +----------- + +The Vicor PLI1209BC is an isolated digital power system supervisorthatprovides
that provides
ack.
Quoted 87 lines
Quoted 87 lines
+a communication interface between a host processor and one Bus Converter Module
+(BCM). The PLI communicates with a system controller via a PMBus compatible
+interface over an isolated UART interface. Through the PLI, the host processorDocumentation/hwmon/pli1209bc.rst new file +6
-0+can configure, set protection limits, and monitor the BCM. + +Sysfs entries +------------- + +===============================================================================
Documentation/hwmon/pli1209bc.rst new file +44
-0+in1_label "vin2" +in1_input Input voltage. +in1_rated_min Minimum rated input voltage. +in1_rated_max Maximum rated input voltage. +in1_max Maximum input voltage. +in1_max_alarm Input voltage high alarm. +in1_crit Critical input voltage. +in1_crit_alarm Input voltage critical alarm. + +in2_label "vout2" +in2_input Output voltage. +in2_rated_min Minimum rated output voltage. +in2_rated_max Maximum rated output voltage. +in2_alarm Output voltage alarm + +curr1_label "iin2" +curr1_input Input current. +curr1_max Maximum input current. +curr1_max_alarm Maximum input current high alarm. +curr1_crit Critical input current. +curr1_crit_alarm Input current critical alarm. + +curr2_label "iout2" +curr2_input Output current. +curr2_crit Critical output current. +curr2_crit_alarm Output current critical alarm. +curr2_max Maximum output current. +curr2_max_alarm Output current high alarm. + +power1_label "pin2" +power1_input Input power. +power1_alarm Input power alarm. + +power2_label "pout2" +power2_input Output power. +power2_rated_max Maximum rated output power. + +temp1_input Die temperature. +temp1_alarm Die temperature alarm. +temp1_max Maximum die temperature. +temp1_max_alarm Die temperature high alarm. +temp1_crit Critical die temperature. +temp1_crit_alarm Die temperature critical alarm. +===============================================================================
drivers/hwmon/pmbus/Kconfig +0
-0@@ -310,6 +310,15 @@ config SENSORS_PIM4328This driver can also be built as a module. If so, the module will
be called pim4328.
+configSENSORS_PLI1209BC
+ tristate "Vicor PLI1209BC"
+ help
+ If you say yes here you get hardware monitoring support for Vicor
+ PLI1209BC Digital Supervisor.
+
+ This driver can also be built as a module. If so, the module will
+ be called pli1209bc.
+
configSENSORS_PM6764TR
tristate "ST PM6764TR"
helpdrivers/hwmon/pmbus/Makefile +0
-1--- a/drivers/hwmon/pmbus/Makefile
Quoted 8 lines
Quoted 6 lines
+++ b/drivers/hwmon/pmbus/Makefile
drivers/hwmon/pmbus/Makefile +0
-0@@ -34,6 +34,7 @@ obj-$(CONFIG_SENSORS_MP2888) += mp2888.oobj-$(CONFIG_SENSORS_MP2975) += mp2975.o obj-$(CONFIG_SENSORS_MP5023) += mp5023.o obj-$(CONFIG_SENSORS_PM6764TR) += pm6764tr.o +obj-$(CONFIG_SENSORS_PLI1209BC) += pli1209bc.o
Alphabetic order please.
ack.
Thanks,
Marcello
Quoted 134 lines
Quoted 134 lines
obj-$(CONFIG_SENSORS_PXE1610) += pxe1610.o obj-$(CONFIG_SENSORS_Q54SJ108A2) += q54sj108a2.o obj-$(CONFIG_SENSORS_STPDDC60) += stpddc60.o
drivers/hwmon/pmbus/pli1209bc.c new file +3
-0@@ -0,0 +1,115 @@ +// SPDX-License-Identifier: GPL-2.0+ +/* +* Hardware monitoring driver for Vicor PLI1209BC Digital Supervisor
+ *
+ * Copyright (c) 2022 9elements GmbH
+ */drivers/hwmon/pmbus/pli1209bc.c new file +8
-0+ +#include <linux/i2c.h> +#include <linux/module.h> +#include <linux/pmbus.h> +#include "pmbus.h" + +/* +* The capability command is only supported at page 0. Probing the device while
+ * the page register is set to 1 will falsely enable PEC support. Disable
+ * capability probing accordingly, since the PLI1209BC does not have any
+ * additional capabilities.
+ */drivers/hwmon/pmbus/pli1209bc.c new file +5
-0+static struct pmbus_platform_data pli1209bc_plat_data = { + .flags = PMBUS_NO_CAPABILITY, +}; + +static int pli1209bc_read_word_data(struct i2c_client *client, intpage,
+ int phase, int reg)drivers/hwmon/pmbus/pli1209bc.c new file +7
-0+{ + int data; + + switch (reg) { + /* PMBUS_READ_POUT uses a direct format with R=0 */ + case PMBUS_READ_POUT: + data = pmbus_read_word_data(client, page, phase,reg);
+ if (data < 0)
+ return data;
+ data =sign_extend32(data, 15)* 10; + returnclamp_val(data, -32768, 32767)&0xffff; + default:
+ return-ENODATA;
+ }drivers/hwmon/pmbus/pli1209bc.c new file +31
-0+} + +static struct pmbus_driver_info pli1209bc_info = { + .pages = 2, + .format[PSC_VOLTAGE_IN] = direct, + .format[PSC_VOLTAGE_OUT] = direct, + .format[PSC_CURRENT_IN] = direct, + .format[PSC_CURRENT_OUT] = direct, + .format[PSC_POWER] = direct, + .format[PSC_TEMPERATURE] = direct, + .m[PSC_VOLTAGE_IN] = 1, + .b[PSC_VOLTAGE_IN] = 0, + .R[PSC_VOLTAGE_IN] = 1, + .m[PSC_VOLTAGE_OUT] = 1, + .b[PSC_VOLTAGE_OUT] = 0, + .R[PSC_VOLTAGE_OUT] = 1, + .m[PSC_CURRENT_IN] = 1, + .b[PSC_CURRENT_IN] = 0, + .R[PSC_CURRENT_IN] = 3, + .m[PSC_CURRENT_OUT] = 1, + .b[PSC_CURRENT_OUT] = 0, + .R[PSC_CURRENT_OUT] = 2, + .m[PSC_POWER] = 1, + .b[PSC_POWER] = 0, + .R[PSC_POWER] = 1, + .m[PSC_TEMPERATURE] = 1, + .b[PSC_TEMPERATURE] = 0, + .R[PSC_TEMPERATURE] = 0, + /* + * Page 0 sums up all attributes except voltage readings. + * The pli1209 digital supervisor only contains a singleBCM, making
+ * page 0 redundant.
+ */
+ .func[1] =PMBUS_HAVE_VIN|PMBUS_HAVE_VOUT+ | PMBUS_HAVE_IIN | PMBUS_HAVE_IOUT + | PMBUS_HAVE_PIN | PMBUS_HAVE_POUT + | PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP + | PMBUS_HAVE_STATUS_IOUT | PMBUS_HAVE_STATUS_INPUT,+ .read_word_data =
pli1209bc_read_word_data,drivers/hwmon/pmbus/pli1209bc.c new file +27
-0+}; + +static int pli1209bc_probe (struct i2c_client *client) +{ + client->dev.platform_data = &pli1209bc_plat_data; + return pmbus_do_probe(client, &pli1209bc_info); +} + +static const struct i2c_device_id pli1209bc_id[] = { + {"pli1209bc", 0}, + {} +}; + +MODULE_DEVICE_TABLE (i2c, pli1209bc_id); + +#ifdef CONFIG_OF +static const struct of_device_id pli1209bc_of_match[] = { + { .compatible = "vicor,pli1209bc" }, + { }, +}; +MODULE_DEVICE_TABLE (of, pli1209bc_of_match); +#endif + +static struct i2c_driver pli1209bc_driver = { + .driver = { + .name = "pli1209bc", + .of_match_table =
of_match_ptr(pli1209bc_of_match),
+ },
+ .probe_new =pli1209bc_probe,
+ .id_table =pli1209bc_id,drivers/hwmon/pmbus/pli1209bc.c new file +8
-0+}; + +module_i2c_driver (pli1209bc_driver); + +MODULE_AUTHOR ("Marcello Sylvester Bauer <[email protected]>" ); +MODULE_DESCRIPTION ("PMBus driver for Vicor PLI1209BC" ); +MODULE_LICENSE ("GPL" ); +MODULE_IMPORT_NS (PMBUS );
PATCH v3 4/4 pmbus (pli1209bc): Add regulator support
In reply to Marcello Sylvester BauerAdd regulator support for PLI1209BC Digital Supervisor.
--- drivers/hwmon/pmbus/Kconfig | 7 +++++++ drivers/hwmon/pmbus/pli1209bc.c | 31 +++++++++++++++++++++++++++++++ 2 files changed, 38 insertions(+)
drivers/hwmon/pmbus/Kconfig +7 -0
@@ -319,6 +319,13 @@ config SENSORS_PLI1209BC This driver can also be built as a module. If so, the module will be called pli1209bc. +config SENSORS_PLI1209BC_REGULATOR + bool "Regulator support for PLI1209BC" + depends on SENSORS_PLI1209BC && REGULATOR + help + If you say yes here you get regulator support for Vicor PLI1209BC + Digital Supervisor. + config SENSORS_PM6764TR tristate "ST PM6764TR" help
drivers/hwmon/pmbus/pli1209bc.c +31 -0
@@ -8,6 +8,7 @@#include <linux/i2c.h> #include <linux/module.h> #include <linux/pmbus.h> +#include <linux/regulator/driver.h> #include "pmbus.h" /*
@@ -33,11 +34,37 @@ static int pli1209bc_read_word_data(struct i2c_client *client, int page,return data; data =sign_extend32 (data,15 ) *10 ;return clamp_val (data,-32768 ,32767 ) &0xffff ; +/* +* PMBUS_READ_VOUT and PMBUS_READ_TEMPERATURE_1 return invalid data +* when the BCM is turned off. Since it is not possible to return +* ENODATA error, return zero instead. +*/ +case PMBUS_READ_VOUT : +case PMBUS_READ_TEMPERATURE_1 : + data =pmbus_read_word_data (client, page, phase, +PMBUS_STATUS_WORD ); +if (data <0 ) +return data; +if (data &PB_STATUS_POWER_GOOD_N ) +return 0 ; +return pmbus_read_word_data (client, page, phase, reg);default :return -ENODATA ; } } +#if IS_ENABLED (CONFIG_SENSORS_PLI1209BC_REGULATOR ) +static const struct regulator_desc pli1209bc_reg_desc = { + .name ="vout2" , + .id =1 , + .of_match =of_match_ptr ("vout2" ), + .regulators_node =of_match_ptr ("regulators" ), + .ops = &pmbus_regulator_ops, + .type =REGULATOR_VOLTAGE , + .owner =THIS_MODULE , +}; +#endif +static struct pmbus_driver_info pli1209bc_info = { .pages =2 , .format[PSC_VOLTAGE_IN ] = direct,
@@ -75,6 +102,10 @@ static struct pmbus_driver_info pli1209bc_info = { | PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP | PMBUS_HAVE_STATUS_IOUT | PMBUS_HAVE_STATUS_INPUT, .read_word_data = pli1209bc_read_word_data, +#if IS_ENABLED(CONFIG_SENSORS_PLI1209BC_REGULATOR) + .num_regulators =1 , + .reg_desc = &pli1209bc_reg_desc, +#endif };static int pli1209bc_probe (struct i2c_client *client)
Signature · 1 line
2.34.1