Skip to content

RFC Add visibility for native NVMe multipath using sysfs

Nilay Shroff linux-nvme 7 versions – Applied

Status from this message: Thanks, applied to nvme-6.14.

Get series with b4
b4 am [email protected]

Versions newest first · linked by author and title

  1. v7 RFC Latest3 patches 4 repliesApplied
  2. v6 RFC3 patches 7 repliesApplied
  3. v5 RFC3 patches 8 repliesSuperseded
Earlier versions · 4
VersionPostedPatchesRepliesStatus
v4 RFC1 patch12 repliesSuperseded
v3 RFC1 patch3 repliesSuperseded
v2 RFC1 patch4 repliesSuperseded
v1 RFC1 patch9 repliesSuperseded

Changes in v7 from the cover letter

- Fix sysfs link warning menifested while running blktest nvme/058 (Keith Busch, Chaitanya Kulkarni)
- Link to v6: https://lore.kernel.org/all/[email protected]/

Patches in v7 Applied

#Subject and filesSizeRepliesApplied
1/3nvme-multipath: Add visibility for round-robin io-policydrivers/nvme/host/core.c drivers/nvme/host/multipath.c drivers/nvme/host/nvme.h +1 more+130 -41 reply
2/3nvme-multipath: Add visibility for numa io-policydrivers/nvme/host/multipath.c drivers/nvme/host/nvme.h drivers/nvme/host/sysfs.c+33 -01 reply
3/3nvme-multipath: Add visibility for queue-depth io-policydrivers/nvme/host/multipath.c drivers/nvme/host/nvme.h drivers/nvme/host/sysfs.c+15 -11 reply

Reviews trailers per patch

All 3 patches have a Reviewed-by or Acked-by.

PatchSagi GrimbergHannes Reinecke
1/3R-b
2/3R-b R-b
3/3R-b R-b

Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes.

Read the v7 thread

Cover letter [PATCHv7 RFC 0/3] Add visibility for native NVMe multipath using sysfs

Hi,

This RFC propose adding new sysfs attributes for adding visibility of nvme native multipath I/O.

The changes are divided into three patches.
The first patch adds visibility for round-robin io-policy. The second patch adds visibility for numa io-policy. The third patch adds the visibility for queue-depth io-policy.

As we know, NVMe native multipath supports three different io policies (numa, round-robin and queue-depth) for selecting I/O path, however, we don't have any visibility about which path is being selected by multipath code for forwarding I/O. This RFC helps add that visibility by adding new sysfs attribute files named "numa_nodes" and "queue_depth" under each namespace block device path /sys/block/nvmeXcYnZ/. We also create a "multipath" sysfs directory under head disk node and then from this directory add a link to each namespace path device this head disk node points to.

Please find below output generated with this proposed RFC patch applied on a system with two multi-controller PCIe NVMe disks attached to it. This system is also an NVMf-TCP host which is connected to an NVMf-TCP target over two NIC cards. This system has four numa nodes online when the below output was captured:

# cat /sys/devices/system/node/online
0-3
# lscpu
<snip>
NUMA:
  NUMA node(s):           4
  NUMA node0 CPU(s):
  NUMA node1 CPU(s):      0-7
  NUMA node2 CPU(s):      8-31
  NUMA node3 CPU(s):      32-63
<snip>

Please note that numa node 0 though online, doesn't have any CPU currently assigned to it.

# nvme list -v
Subsystem        Subsystem-NQN                                                                                    Controllers
---------------- ------------------------------------------------------------------------------------------------ ----------------
nvme-subsys1     nqn.1994-11.com.samsung:nvme:PM1735a:2.5-inch:S6RTNE0R900057                                     nvme0, nvme1
nvme-subsys3     nqn.2019-10.com.kioxia:KCM7DRUG1T92:3D60A04906N1                                                 nvme2, nvme3
nvme-subsys4     nvmet_subsystem                                                                                  nvme4, nvme5

Device Cntlid SN MN FR TxPort Address Slot Subsystem Namespaces
---------------- ------ -------------------- ---------------------------------------- -------- ------ -------------- ------ ------------ ----------------

nvme0    66     S6RTNE0R900057       3.2TB NVMe Gen4 U.2 SSD III              REV.SN66 pcie   052e:78:00.0   U50EE.001.WZS000E-P3-C14-R1 nvme-subsys1 nvme1n1
nvme1    65     S6RTNE0R900057       3.2TB NVMe Gen4 U.2 SSD III              REV.SN66 pcie   058e:78:00.0   U50EE.001.WZS000E-P3-C14-R2 nvme-subsys1 nvme1n1
nvme2    2      3D60A04906N1         1.6TB NVMe Gen4 U.2 SSD IV               REV.CAS2 pcie   0524:28:00.0   U50EE.001.WZS000E-P3-C4-R1 nvme-subsys3 nvme3n1
nvme3    1      3D60A04906N1         1.6TB NVMe Gen4 U.2 SSD IV               REV.CAS2 pcie   0584:28:00.0   U50EE.001.WZS000E-P3-C4-R2 nvme-subsys3 nvme3n1
nvme4    1      a224673364d1dcb6fab9 Linux                                    6.9.0-rc tcp    traddr=20.0.0.200,trsvcid=4420,src_addr=20.0.0.100        nvme-subsys4 nvme4n1
nvme5    2      a224673364d1dcb6fab9 Linux                                    6.9.0-rc tcp    traddr=10.0.0.200,trsvcid=4420,src_addr=10.0.0.100        nvme-subsys4 nvme4n1

Device Generic NSID Usage Format Controllers
----------------- ----------------- ---------- -------------------------- ---------------- ----------------

/dev/nvme1n1 /dev/ng1n1   0x1          5.75  GB /   5.75  GB      4 KiB +  0 B   nvme0, nvme1
/dev/nvme3n1 /dev/ng3n1   0x2          0.00   B /   5.75  GB      4 KiB +  0 B   nvme2, nvme3
/dev/nvme4n1 /dev/ng4n1   0x1          5.75  GB /   5.75  GB      4 KiB +  0 B   nvme4, nvme5
# nvme show-topology
nvme-subsys1 - NQN=nqn.1994-11.com.samsung:nvme:PM1735a:2.5-inch:S6RTNE0R900057
               hostnqn=nqn.2014-08.org.nvmexpress:uuid:41528538-e8ad-4eaf-84a7-9c552917d988
               iopolicy=numa
\
 +- ns 1
 \
  +- nvme0 pcie 052e:78:00.0 live optimized
  +- nvme1 pcie 058e:78:00.0 live optimized

nvme-subsys3 - NQN=nqn.2019-10.com.kioxia:KCM7DRUG1T92:3D60A04906N1

               hostnqn=nqn.2014-08.org.nvmexpress:uuid:41528538-e8ad-4eaf-84a7-9c552917d988
               iopolicy=round-robin
\
 +- ns 2
 \
  +- nvme2 pcie 0524:28:00.0 live optimized
  +- nvme3 pcie 0584:28:00.0 live optimized

nvme-subsys4 - NQN=nvmet_subsystem

               hostnqn=nqn.2014-08.org.nvmexpress:uuid:41528538-e8ad-4eaf-84a7-9c552917d988
               iopolicy=queue-depth
\
 +- ns 1
 \
  +- nvme4 tcp traddr=20.0.0.200,trsvcid=4420,src_addr=20.0.0.100 live optimized
  +- nvme5 tcp traddr=10.0.0.200,trsvcid=4420,src_addr=10.0.0.100 live optimized

As we could see above, we've three shared namespaces created. In terms of iopolicy, we have "numa" configured for nvme-subsys1, "round-robin" configured for nvme-subsys3 and "queue-depth" configured for nvme-subsys4.

Now, under each namespace "head disk node", we create a sysfs group attribute named "multipath". The "multipath" group then points to the each path this head disk node points to:

# tree /sys/block/nvme1n1/multipath/
/sys/block/nvme1n1/multipath/
├── nvme1c0n1 -> ../../../../../pci052e:78/052e:78:00.0/nvme/nvme0/nvme1c0n1
└── nvme1c1n1 -> ../../../../../pci058e:78/058e:78:00.0/nvme/nvme1/nvme1c1n1
# tree /sys/block/nvme3n1/multipath/
/sys/block/nvme3n1/multipath/
├── nvme3c2n1 -> ../../../../../pci0524:28/0524:28:00.0/nvme/nvme2/nvme3c2n1
└── nvme3c3n1 -> ../../../../../pci0584:28/0584:28:00.0/nvme/nvme3/nvme3c3n1
# tree /sys/block/nvme4n1/multipath/
/sys/block/nvme4n1/multipath/
├── nvme4c4n1 -> ../../../../nvme-fabrics/ctl/nvme4/nvme4c4n1
└── nvme4c5n1 -> ../../../../nvme-fabrics/ctl/nvme5/nvme4c5n1

One can easily infer from the above output that for the "round-robin" I/O policy, configured under nvme-subsys3, the I/O workload targeted at nvme3n1 would toggle across nvme3c2n1 and nvme3c3n1 assuming the ana state of each path is optimized (as can be seen in the output of show-topology).

For numa I/O policy, configured under nvme-subsys1, the "numa_nodes" attribute file shows the numa nodes being preferred by the respective namespace path. The numa nodes value is comma delimited list of nodes or A-B range of nodes.

# cat  /sys/block/nvme1n1/multipath/nvme1c0n1/numa_nodes
0-1
# cat  /sys/block/nvme1n1/multipath/nvme1c1n1/numa_nodes
2-3

From the above output, one can easily infer that I/O workload targeted at nvme1n1 and running on numa nodes 0 and 1 would use path nvme1c0n1. Similarly, I/O workload running on numa nodes 2 and 3 would use path nvme1c1n1.

For queue-depth I/O policy, configured under nvme-subsys4, the "queue_depth" attribute file shows the number of active/in-flight I/O requests currently queued for each path.

# cat  /sys/block/nvme4n1/multipath/nvme4c4n1/queue_depth
518
# cat  /sys/block/nvme4n1/multipath/nvme4c5n1/queue_depth
504

From the above output, one can easily infer that I/O workload targeted at nvme4n1 uses two paths nvme4c4n1 and nvme4c5n1 and the current queue depth of each path is 518 and 504 respectively.

Changes since v6:
- Fix sysfs link warning menifested while running blktest nvme/058 (Keith Busch, Chaitanya Kulkarni)
- Link to v6: https://lore.kernel.org/all/[email protected]/
Changes since v5:
- Fix typo in the subject line of the first patch in the series (Danied Wagner)
- Link to v5: https://lore.kernel.org/all/[email protected]/
changes since v4:
- Ensure that we create sysfs link from head gendisk node to each path device irrespective of the ANA state of the path (Hannes Reinecke)
- Split the patch into three patch series and add commentary in the
code so that it's easy to read and understand the core logic (Sagi Grimberg)
- Don't show any output if user reads "numa_nodes" file and configured iopolicy is anything but numa; similarly don't emit any output if user reads "queue_depth" file and configured iopolicy is anything but queue-depth (Sagi Grimberg)
- Link to v4: https://lore.kernel.org/all/[email protected]/

Changes since v3:
- Protect the namespace dereference code with srcu read lock (Daniel Wagner)
- Link to v3: https://lore.kernel.org/all/[email protected]/

Changes since v2:
- Use one value per one sysfs attribute (Keith Busch)
- Link to v2: https://lore.kernel.org/all/[email protected]/

Changes since v1:
- Use sysfs to export multipath I/O information instead of debugfs
- Link to v1: https://lore.kernel.org/all/[email protected]/

Nilay Shroff (3):
nvme-multipath: Add visibility for round-robin io-policy
nvme-multipath: Add visibility for numa io-policy
nvme-multipath: Add visibility for queue-depth io-policy

 drivers/nvme/host/core.c      |   3 +
 drivers/nvme/host/multipath.c | 138 ++++++++++++++++++++++++++++++++++
 drivers/nvme/host/nvme.h      |  20 ++++-
 drivers/nvme/host/sysfs.c     |  20 +++++
 4 files changed, 177 insertions(+), 4 deletions(-)
Signature · 1 line