Hi,

I was referred to this email address by Juan Nu?ez Quesada, the application support engineer assigned to our IPS case.

We have a BMC connected to Rangeley (Atom C2000) via the NC-SI interface. We are able to get to the LAN to/from the BMC, so that works. The issue is that while Linux is booting, the IGB driver loads and resets the NC-SI interface, causing us to lose connection with the BMC. We can reconnect after the reset, but that is not acceptable to the customer
. They need a solid
connection.

We would like to understand how and why the IGB driver is resetting the NC-SI interface. That technically should not happen
the NC-SI interface
should be up at all times so that the BMC can stay on the network even when Rangeley is shut down.

As an experiment, I did try modifying some EEPROM settings to prevent the IGB driver from resetting the interface. Specifically, I cleared bit 0 of the Initialization Control 4 word in the EEPROM (LAN base address + Offset 0x13) to disable software reset. This does not appear to have an effect.

Please assist. Thanks!