PATCH 1/1 hwmon: (jc42) Allow negative hysteresis temperatures

The driver supports negative high and critical limits, it can return negative hysteresis values, so there is no good reason to not let the user write negative hysteresis values.

---
 drivers/hwmon/jc42.c |    7 ++++---
 1 file changed, 4 insertions(+), 3 deletions(-)
drivers/hwmon/jc42.c +4 -3
@@ -304,15 +304,16 @@ static ssize_t set_temp_crit_hyst(struct
 				  const char *buf, size_t count)
 {
 	struct jc42_data *data = dev_get_drvdata(dev);
-	unsigned long val;
+	long val;
 	int diff, hyst;
 	int err;
 	int ret = count;
 
-	if (kstrtoul(buf, 10, &val) < 0)
+	if (kstrtol(buf, 10, &val) < 0)
 		return -EINVAL;
 
-	val = clamp_val(val, 0, JC42_TEMP_MAX);
+	val = clamp_val(val, (data->extended ? JC42_TEMP_MIN_EXTENDED :
+			      JC42_TEMP_MIN) - 6000, JC42_TEMP_MAX);
 	diff = jc42_temp_from_reg(data->temp[t_crit]) - val;
 
 	hyst = 0;
Signature · 7 lines
Jean Delvare
SUSE L3 Support

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
maintainer
#1 lore raw
Quoted 7 lines · Jean Delvare

The driver supports negative high and critical limits, it can return negative hysteresis values, so there is no good reason to not let the user write negative hysteresis values.

---

Hi Jean,

thanks for looking into this. Applied.

Thanks,
Guenter