thermal: imx8mm_thermal: wait for a valid measurement

PATCH NAK Marcus Folkesson 2 participants 3 messages Oct 7, 2022 – Oct 14, 2022

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 thermal: imx8mm_thermal: wait for a valid measurement

Check if first measurement is still pending or if temperature is out of range.
Return and try again later if that is the case.

Fixes 5eed800a6811 ("thermal: imx8mm: Add support for i.MX8MM thermal monitoring unit")

---

Notes:
v2: Also invalidate if temperature > max (125 degrees C)

 drivers/thermal/imx8mm_thermal.c | 12 +++++++++---
 1 file changed, 9 insertions(+), 3 deletions(-)
drivers/thermal/imx8mm_thermal.c +9 -3
index af666bd9e8d4..e42bf373cebc 100644
@@ -62,11 +62,17 @@ static int imx8mm_tmu_get_temp(void *data, int *temp)
 {
 	struct tmu_sensor *sensor = data;
 	struct imx8mm_tmu *tmu = sensor->priv;
-	u32 val;
+	bool ready;
+	unsigned long val;
+
+	val = readl_relaxed(tmu->base + TRITSR);
+	ready = test_bit(probe_status_offset(1), &val);
+	if (!ready)
+		return -EAGAIN;
 
-	val = readl_relaxed(tmu->base + TRITSR) & TRITSR_TEMP0_VAL_MASK;
+	val = val & TRITSR_TEMP0_VAL_MASK;
 	*temp = val * 1000;
-	if (*temp < VER1_TEMP_LOW_LIMIT)
+	if (*temp < VER1_TEMP_LOW_LIMIT || *temp > VER2_TEMP_HIGH_LIMIT)
 		return -EAGAIN;
 
 	return 0;
Signature · 1 line
2.37.1
#1 lore raw
Quoted 6 lines · Marcus Folkesson

Check if first measurement is still pending or if temperature is out of range.
Return and try again later if that is the case.

Fixes 5eed800a6811 ("thermal: imx8mm: Add support for i.MX8MM thermal monitoring unit")

NAK:
Please refer: https://www.nxp.com/docs/en/errata/IMX8MM_0N87W.pdf
ERR051272: TMU: Bit 31 of registers TMU_TSCR/TMU_TRITSR/TMU_TRATSR invalid

Thanks,
Peng.

Quoted 33 lines

---

Notes:
v2: Also invalidate if temperature > max (125 degrees C)

  drivers/thermal/imx8mm_thermal.c | 12 +++++++++---
  1 file changed, 9 insertions(+), 3 deletions(-)
drivers/thermal/imx8mm_thermal.c +9 -3
index af666bd9e8d4..e42bf373cebc 100644
@@ -62,11 +62,17 @@ static int imx8mm_tmu_get_temp(void *data, int *temp)
  {
  	struct tmu_sensor *sensor = data;
  	struct imx8mm_tmu *tmu = sensor->priv;
-	u32 val;
+	bool ready;
+	unsigned long val;
+
+	val = readl_relaxed(tmu->base + TRITSR);
+	ready = test_bit(probe_status_offset(1), &val);
+	if (!ready)
+		return -EAGAIN;
 
-	val = readl_relaxed(tmu->base + TRITSR) & TRITSR_TEMP0_VAL_MASK;
+	val = val & TRITSR_TEMP0_VAL_MASK;
  	*temp = val * 1000;
-	if (*temp < VER1_TEMP_LOW_LIMIT)
+	if (*temp < VER1_TEMP_LOW_LIMIT || *temp > VER2_TEMP_HIGH_LIMIT)
  		return -EAGAIN;
 
  	return 0;
#2 lore raw

Hi Peng,

Quoted 7 lines · Peng Fan
Quoted 4 lines · Marcus Folkesson

Check if first measurement is still pending or if temperature is out of range.
Return and try again later if that is the case.

Quoted 6 lines
Quoted 2 lines
Fixes 5eed800a6811 ("thermal: imx8mm: Add support for i.MX8MM thermal monitoring unit")

NAK:
Please refer: https://www.nxp.com/docs/en/errata/IMX8MM_0N87W.pdf
ERR051272: TMU: Bit 31 of registers TMU_TSCR/TMU_TRITSR/TMU_TRATSR invalid

I see, thank you.

I think it is still worth to check the upper limit though, so I will send a patch for that.

Quoted 3 lines

Thanks,
Peng.

Best regards,
Marcus Folkesson