flow offload teardown when layer 2 roaming
Subsystems (3)
v3 cover flow offload teardown when layer 2 roaming
This patch-set can be reviewed separately from my submissions concerning the bridge-fastpath.
In case of a bridge in the forward-fastpath or bridge-fastpath the fdb is used to create the tuple. In case of roaming at layer 2 level, for example 802.11r, the destination device is changed in the fdb. The destination device of a direct transmitting tuple is no longer valid and traffic is send to the wrong destination. Also the hardware offloaded fastpath is not valid anymore.
This flowentry needs to be torn down asap. Also make sure that the flow entry is not being used, when marked for teardown.
Changes in v3:
- static nf_flow_table_switchdev_nb.
Changes in v2:
- Unchanged, only tags RFC net-next to PATCH nf-next.
Eric Woudstra (3):
netfilter: flow: Add bridge_vid member
netfilter: nf_flow_table_core: teardown direct xmit when destination
changed
netfilter: nf_flow_table_ip: don't follow fastpath when marked
teardown
include/net/netfilter/nf_flow_table.h | 2 + net/netfilter/nf_flow_table_core.c | 66 +++++++++++++++++++++++++++ net/netfilter/nf_flow_table_ip.c | 6 +++ net/netfilter/nft_flow_offload.c | 3 ++ 4 files changed, 77 insertions(+)
Signature · 1 line
2.47.1
PATCH v3 1/3 netfilter: flow: Add bridge_vid member
Store the vid used on the bridge in the flow_offload_tuple, so it can be used later to identify fdb entries that relate to the tuple.
The bridge_vid member is added to the structures nft_forward_info, nf_flow_route and flow_offload_tuple. It can now be passed from net_device_path->bridge.vlan_id to flow_offload_tuple->out.bridge_vid.
--- include/net/netfilter/nf_flow_table.h | 2 ++ net/netfilter/nf_flow_table_core.c | 1 + net/netfilter/nft_flow_offload.c | 3 +++ 3 files changed, 6 insertions(+)
include/net/netfilter/nf_flow_table.h +2 -0
@@ -146,6 +146,7 @@ struct flow_offload_tuple {struct {u32 ifidx;u32 hw_ifidx; +u16 bridge_vid;u8 h_source[ETH_ALEN ];u8 h_dest[ETH_ALEN ]; } out;
@@ -212,6 +213,7 @@ struct nf_flow_route {struct {u32 ifindex;u32 hw_ifindex; +u16 bridge_vid;u8 h_source[ETH_ALEN ];u8 h_dest[ETH_ALEN ]; } out;
net/netfilter/nf_flow_table_core.c +1 -0
@@ -128,6 +128,7 @@ static int flow_offload_fill_route(struct flow_offload *flow, ETH_ALEN); flow_tuple->out.ifidx = route->tuple[dir].out.ifindex; flow_tuple->out.hw_ifidx = route->tuple[dir].out.hw_ifindex; + flow_tuple->out.bridge_vid = route->tuple[dir].out.bridge_vid;dst_release (dst);break ;case FLOW_OFFLOAD_XMIT_XFRM :
net/netfilter/nft_flow_offload.c +3 -0
@@ -85,6 +85,7 @@ struct nft_forward_info {__u16 id;__be16 proto; } encap[NF_FLOW_TABLE_ENCAP_MAX ]; +u16 bridge_vid;u8 num_encaps;u8 ingress_vlans;u8 h_source[ETH_ALEN ];
@@ -159,6 +160,7 @@ static void nft_dev_path_info(const struct net_device_path_stack *stack,case DEV_PATH_BR_VLAN_KEEP :break ; } + info->bridge_vid = path->bridge.vlan_id; info->xmit_type =FLOW_OFFLOAD_XMIT_DIRECT ;break ;default :
@@ -223,6 +225,7 @@ static void nft_dev_forward_path(struct nf_flow_route *route,memcpy (route->tuple[dir].out.h_dest, info.h_dest,ETH_ALEN ); route->tuple[dir].out.ifindex = info.outdev->ifindex; route->tuple[dir].out.hw_ifindex = info.hw_outdev->ifindex; + route->tuple[dir].out.bridge_vid = info.bridge_vid; route->tuple[dir].xmit_type = info.xmit_type; } }
Signature · 1 line
2.47.1
PATCH v3 2/3 netfilter: nf_flow_table_core: teardown direct xmit when destination changed
In reply to Eric WoudstraIn case of a bridge in the forward-fastpath or bridge-fastpath the fdb is used to create the tuple. In case of roaming at layer 2 level, for example 802.11r, the destination device is changed in the fdb. The destination device of a direct transmitting tuple is no longer valid and traffic is send to the wrong destination. Also the hardware offloaded fastpath is not valid anymore.
In case of roaming, a switchdev notification is send to delete the old fdb entry. Upon receiving this notification, mark all direct transmitting flows with the same ifindex, vid and hardware address as the fdb entry to be teared down. The hardware offloaded fastpath is still in effect, so minimize the delay of the work queue by setting the delay to zero.
--- net/netfilter/nf_flow_table_core.c | 65 ++++++++++++++++++++++++++++++ 1 file changed, 65 insertions(+)
net/netfilter/nf_flow_table_core.c +65 -0
@@ -13,6 +13,7 @@#include <net/netfilter/nf_conntrack_core.h> #include <net/netfilter/nf_conntrack_l4proto.h> #include <net/netfilter/nf_conntrack_tuple.h> +#include <net/switchdev.h> static DEFINE_MUTEX (flowtable_lock);static LIST_HEAD (flowtables);
@@ -745,6 +746,63 @@ void nf_flow_table_cleanup(struct net_device *dev) }EXPORT_SYMBOL_GPL (nf_flow_table_cleanup); +struct flow_cleanup_data { +const unsigned char *addr; +int ifindex; +u16 vid; +bool found; +}; + +static void nf_flow_table_do_cleanup_addr (struct nf_flowtable *flow_table, +struct flow_offload *flow,void *data) +{ +struct flow_cleanup_data *cud = data; + +if ((flow->tuplehash[0 ].tuple.xmit_type ==FLOW_OFFLOAD_XMIT_DIRECT && + flow->tuplehash[0 ].tuple.out.ifidx == cud->ifindex && + flow->tuplehash[0 ].tuple.out.bridge_vid == cud->vid && +ether_addr_equal (flow->tuplehash[0 ].tuple.out.h_dest, cud->addr)) || + (flow->tuplehash[1 ].tuple.xmit_type ==FLOW_OFFLOAD_XMIT_DIRECT && + flow->tuplehash[1 ].tuple.out.ifidx == cud->ifindex && + flow->tuplehash[1 ].tuple.out.bridge_vid == cud->vid && +ether_addr_equal (flow->tuplehash[1 ].tuple.out.h_dest, cud->addr))) { +flow_offload_teardown (flow); + cud->found = true; + } +} + +static int nf_flow_table_switchdev_event (struct notifier_block *unused, +unsigned long event,void *ptr) +{ +struct switchdev_notifier_fdb_info *fdb_info; +struct nf_flowtable *flowtable; +struct flow_cleanup_data cud; + +if (event !=SWITCHDEV_FDB_DEL_TO_DEVICE ) +return NOTIFY_DONE ; + + fdb_info = ptr; + cud.addr = fdb_info->addr; + cud.vid = fdb_info->vid; + cud.ifindex = fdb_info->info.dev->ifindex; + +mutex_lock (&flowtable_lock); +list_for_each_entry (flowtable, &flowtables, list) { + cud.found = false; +nf_flow_table_iterate (flowtable, nf_flow_table_do_cleanup_addr, &cud); +if (cud.found) +mod_delayed_work (system_power_efficient_wq, + &flowtable->gc_work,0 ); + } +mutex_unlock (&flowtable_lock); + +return NOTIFY_DONE ; +} + +static struct notifier_block nf_flow_table_switchdev_nb__read_mostly = { + .notifier_call = nf_flow_table_switchdev_event, +}; +void nf_flow_table_free (struct nf_flowtable *flow_table) {mutex_lock (&flowtable_lock);
@@ -818,6 +876,10 @@ static int __init nf_flow_table_module_init(void)if (ret) goto out_offload; + ret =register_switchdev_notifier (&nf_flow_table_switchdev_nb); +if (ret <0 ) + goto out_sw_noti; + ret =nf_flow_register_bpf ();if (ret) goto out_bpf;
@@ -825,6 +887,8 @@ static int __init nf_flow_table_module_init(void)return 0 ; out_bpf: +unregister_switchdev_notifier (&nf_flow_table_switchdev_nb); +out_sw_noti:nf_flow_table_offload_exit (); out_offload:unregister_pernet_subsys (&nf_flow_table_net_ops);
@@ -833,6 +897,7 @@ static int __init nf_flow_table_module_init(void) static void __exit nf_flow_table_module_exit(void) { +unregister_switchdev_notifier (&nf_flow_table_switchdev_nb);nf_flow_table_offload_exit ();unregister_pernet_subsys (&nf_flow_table_net_ops); }
Signature · 1 line
2.47.1
PATCH v3 3/3 netfilter: nf_flow_table_ip: don't follow fastpath when marked teardown
In reply to Eric WoudstraWhen a flow is marked for teardown, because the destination is not valid any more, the software fastpath may still be in effect and traffic is still send to the wrong destination. Change the ip/ipv6 hooks to not use the software fastpath for a flow that is marked to be teared down and let the packet continue along the normal path.
--- net/netfilter/nf_flow_table_ip.c | 6 ++++++ 1 file changed, 6 insertions(+)
net/netfilter/nf_flow_table_ip.c +6 -0
@@ -542,6 +542,9 @@ nf_flow_offload_ip_hook(void *priv, struct sk_buff *skb, dir = tuplehash->tuple.dir; flow = container_of(tuplehash, struct flow_offload, tuplehash[dir]); +if (test_bit (NF_FLOW_TEARDOWN , &flow->flags)) +return NF_ACCEPT ; +switch (tuplehash->tuple.xmit_type) {case FLOW_OFFLOAD_XMIT_NEIGH : rt =dst_rtable (tuplehash->tuple.dst_cache);
@@ -838,6 +841,9 @@ nf_flow_offload_ipv6_hook(void *priv, struct sk_buff *skb, dir = tuplehash->tuple.dir; flow = container_of(tuplehash, struct flow_offload, tuplehash[dir]); +if (test_bit (NF_FLOW_TEARDOWN , &flow->flags)) +return NF_ACCEPT ; +switch (tuplehash->tuple.xmit_type) {case FLOW_OFFLOAD_XMIT_NEIGH : rt =dst_rt6_info (tuplehash->tuple.dst_cache);
Signature · 1 line
2.47.1
Quoted 26 lines · Eric Woudstra
This patch-set can be reviewed separately from my submissions concerning the bridge-fastpath.
In case of a bridge in the forward-fastpath or bridge-fastpath the fdb is used to create the tuple. In case of roaming at layer 2 level, for example 802.11r, the destination device is changed in the fdb. The destination device of a direct transmitting tuple is no longer valid and traffic is send to the wrong destination. Also the hardware offloaded fastpath is not valid anymore.
This flowentry needs to be torn down asap. Also make sure that the flow entry is not being used, when marked for teardown.
Changes in v3:
- staticnf_flow_table_switchdev_nb.Changes in v2:
- Unchanged, only tags RFC net-next to PATCH nf-next.Eric Woudstra (3):
netfilter: flow: Addbridge_vidmember
netfilter:nf_flow_table_core: teardown direct xmit when destination
changed
netfilter:nf_flow_table_ip: don't follow fastpath when marked
teardown
Quoted 6 lines
include/net/netfilter/nf_flow_table.h | 2 + net/netfilter/nf_flow_table_core.c | 66 +++++++++++++++++++++++++++ net/netfilter/nf_flow_table_ip.c | 6 +++ net/netfilter/nft_flow_offload.c | 3 ++ 4 files changed, 77 insertions(+)
What is the status of this patch-set? Is it still being considered to be applied? Should I re-submit it? Anything I can do, please let me know.
Florian Westphal
maintainerQuoted 20 lines · Eric Woudstra
Quoted 13 lines
Changes in v3:
- staticnf_flow_table_switchdev_nb.Changes in v2:
- Unchanged, only tags RFC net-next to PATCH nf-next.Eric Woudstra (3):
netfilter: flow: Addbridge_vidmember
netfilter:nf_flow_table_core: teardown direct xmit when destination
changed
netfilter:nf_flow_table_ip: don't follow fastpath when marked
teardownQuoted 6 lines
include/net/netfilter/nf_flow_table.h | 2 + net/netfilter/nf_flow_table_core.c | 66 +++++++++++++++++++++++++++ net/netfilter/nf_flow_table_ip.c | 6 +++ net/netfilter/nft_flow_offload.c | 3 ++ 4 files changed, 77 insertions(+)
Quoted 2 lines
What is the status of this patch-set? Is it still being considered to be applied? Should I re-submit it? Anything I can do, please let me know.
Its marked as 'Changes Requested' in patchwork but I see no feedback on patchwork or lore archives.
Pablo, do you have any objections to this patchset?
AFAICS this is ok and I'd apply this patchset.
Pablo Neira Ayuso
maintainerRe: [PATCH v3 nf-next 3/3] netfilter: nf_flow_table_ip: don't follow fastpath when marked teardown
In reply to Eric WoudstraQuoted 16 lines · Eric Woudstra
When a flow is marked for teardown, because the destination is not valid any more, the software fastpath may still be in effect and traffic is still send to the wrong destination. Change the ip/ipv6 hooks to not use the software fastpath for a flow that is marked to be teared down and let the packet continue along the normal path.
Signed-off-by Eric Woudstra <[email protected]>--- net/netfilter/nf_flow_table_ip.c | 6 ++++++ 1 file changed, 6 insertions(+)net/netfilter/nf_flow_table_ip.c +0
-0
net/netfilter/nf_flow_table_ip.c nf_flow_offload_ip_hook(void *priv, struct sk_buff *skb, · line 546
Quoted 5 lines
net/netfilter/nf_flow_table_ip.c +2
-0@@ -542,6 +542,9 @@ nf_flow_offload_ip_hook(void *priv, struct sk_buff *skb, dir = tuplehash->tuple.dir; flow = container_of(tuplehash, struct flow_offload, tuplehash[dir]); +if (test_bit (NF_FLOW_TEARDOWN , &flow->flags)) +return NF_ACCEPT ;
nf_flow_offload_lookup() already checks for this bit, I don't a benefit from this re-check.
Florian Westphal
maintainerRe: [PATCH v3 nf-next 2/3] netfilter: nf_flow_table_core: teardown direct xmit when destination changed
In reply to Eric WoudstraQuoted 6 lines · Eric Woudstra
net/netfilter/nf_flow_table_core.c +6
-0+static int nf_flow_table_switchdev_event (struct notifier_block *unused, +unsigned long event,void *ptr) +{ +struct switchdev_notifier_fdb_info *fdb_info; +struct nf_flowtable *flowtable; +struct flow_cleanup_data cud;
net/netfilter/nf_flow_table_core.c void nf_flow_table_cleanup(struct net_device *dev) · line 789
Quoted 10 lines
net/netfilter/nf_flow_table_core.c +10
-0+ +if (event !=SWITCHDEV_FDB_DEL_TO_DEVICE ) +return NOTIFY_DONE ; + + fdb_info = ptr; + cud.addr = fdb_info->addr; + cud.vid = fdb_info->vid; + cud.ifindex = fdb_info->info.dev->ifindex; + +mutex_lock (&flowtable_lock);
Please always test your patches with lockdep enabled, this doesn't work. Switchdev notifiers are atomic.
BUG: sleeping function called from invalid context at kernel/locking/mutex.c:575
in_atomic(): 1, irqs_disabled(): 0, non_block: 0, pid: 1570, name: kworker/u32:8preempt_count: 201, expected: 0
RCU nest depth: 1, expected: 0
6 locks held by kworker/u32:8/1570:
#0: ffff88810032b948 ((wq_completion)netns){+.+.}-{0:0}, at: process_scheduled_works+0x8d7/0x1460 #1: ffffc900021e7ba0 (net_cleanup_work){+.+.}-{0:0}, at: process_scheduled_works+0x912/0x1460 #2: ffffffff848d1eb0 (pernet_ops_rwsem){++++}-{4:4}, at: cleanup_net+0xf8/0x7b0 #3: ffffffff848de6e8 (rtnl_mutex){+.+.}-{4:4}, at: ops_undo_list+0x270/0x860
#4: ffff88811f1f8bd8 (&br->hash_lock){+...}-{3:3}, at: br_fdb_delete_by_port+0x3b/0x290 #5: ffffffff8457a800 (rcu_read_lock){....}-{1:3}, at: atomic_notifier_call_chain+0x27/0x150
Workqueue: netns cleanup_net Call Trace: __mutex_lock+0xf5/0x14f0 nf_flow_table_switchdev_event+0x104/0x270 atomic_notifier_call_chain+0xc5/0x150 br_switchdev_fdb_notify+0x2b2/0x330
...