phy: keep the BCMR_LOOPBACK bit while setup forced mode
Subsystems (3)
PATCH 1/1 phy: keep the BCMR_LOOPBACK bit while setup forced mode
When tested the PHY SGMII Loopback,:
1.set the LOOPBACK bit,
2.set the autoneg to AUTONEG_DISABLE, it calls the genphy_setup_forced which will clear the bit.
So just keep the LOOPBACK bit while setup forced mode.
Signed-off-by Weidong Wang <[email protected]>
--- drivers/net/phy/phy_device.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/net/phy/phy_device.c +2 -0
@@ -1124,7 +1124,9 @@ static int genphy_config_advert(struct phy_device *phydev)int genphy_setup_forced (struct phy_device *phydev) {int ctl =0 ; +int val =phy_read (phydev,MII_BMCR ); + ctl |= val &BMCR_LOOPBACK ; phydev->pause =0 ; phydev->asym_pause =0 ;
Signature · 1 line
2.7.0