iio: distance: srf08: add driver ABI documentation
Andreas Klinger
maintainerPATCH v4 3/3 iio: distance: srf08: add driver ABI documentation
Add sysfs-bus-iio-distance-srf08 for individual attributes of the driver, especially:
- sensitivity which the device documentation calls gain for amplifying the signal
- max_range for limiting the maximum distance for expected echos and therefore limiting the time waiting for telegrams
Signed-off-by Andreas Klinger <ak-n176/[email protected]>
--- .../ABI/testing/sysfs-bus-iio-distance-srf08 | 22 ++++++++++++++++++++++ 1 file changed, 22 insertions(+) create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-distance-srf08
Documentation/ABI/testing/sysfs-bus-iio-distance-srf08 new file +22 -0
@@ -0,0 +1,22 @@ +What /sys/bus/iio/devices/iio:deviceX/sensor_sensitivity +Date: January 2017 +KernelVersion: 4.11 +Contact: [email protected] +Description: + Show or set the gain boost of the amp, from 0-31 range. + default 31 + +What /sys/bus/iio/devices/iio:deviceX/sensor_max_range +Date: January 2017 +KernelVersion: 4.11 +Contact: [email protected] +Description: + Show or set the maximum range between the sensor and the + first object echoed in meters. Default value is 6.020. + This setting limits the time the driver is waiting for a + echo. + Showing the range of available values is represented as the + minimum value, the step and the maximum value, all enclosed + in square brackets. + Example: + [0.043 0.043 11.008]
Signature · 1 line
2.1.4
Quoted 8 lines · Andreas Klinger
Add sysfs-bus-iio-distance-srf08 for individual attributes of the driver, especially:
- sensitivity which the device documentation calls gain for amplifying the signal
-max_rangefor limiting the maximum distance for expected echos and therefore limiting the time waiting for telegramsSigned-off-by Andreas Klinger <[email protected]>
Nice clear docs. Thanks,
Applied.
Quoted 34 lines
--- .../ABI/testing/sysfs-bus-iio-distance-srf08 | 22 ++++++++++++++++++++++ 1 file changed, 22 insertions(+) create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-distance-srf08Documentation/ABI/testing/sysfs-bus-iio-distance-srf08 new file +22
-0@@ -0,0 +1,22 @@ +What /sys/bus/iio/devices/iio:deviceX/sensor_sensitivity +Date: January 2017 +KernelVersion: 4.11 +Contact: [email protected] +Description: + Show or set the gain boost of the amp, from 0-31 range. + default 31 + +What /sys/bus/iio/devices/iio:deviceX/sensor_max_range +Date: January 2017 +KernelVersion: 4.11 +Contact: [email protected] +Description: + Show or set the maximum range between the sensor and the + first object echoed in meters. Default value is 6.020. + This setting limits the time the driver is waiting for a + echo. + Showing the range of available values is represented as the + minimum value, the step and the maximum value, all enclosed + in square brackets. + Example: + [0.043 0.043 11.008]