PATCH 2/4 target: log Data-Out timeouts as errors

Data-Out timeouts resulting in connection outages should be logged as errors.

---
 drivers/target/iscsi/iscsi_target_erl1.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/target/iscsi/iscsi_target_erl1.c +3 -3
index 5efa42b939a1..d75cc11ca83c 100644
@@ -1169,13 +1169,13 @@ void iscsit_handle_dataout_timeout(struct timer_list *t)
 	na = iscsit_tpg_get_node_attrib(sess);
 
 	if (!sess->sess_ops->ErrorRecoveryLevel) {
-		pr_debug("Unable to recover from DataOut timeout while"
-			" in ERL=0.\n");
+		pr_err("Unable to recover from DataOut timeout while"
+			" in ERL=0, closing iSCSI connection.\n");
 		goto failure;
 	}
 
 	if (++cmd->dataout_timeout_retries = na->dataout_timeout_retries) {
-		pr_debug("Command ITT: 0x%08x exceeded max retries"
+		pr_err("Command ITT: 0x%08x exceeded max retries"
 			" for DataOUT timeout %u, closing iSCSI connection.\n",
 			cmd->init_task_tag, na->dataout_timeout_retries);
 		goto failure;
Signature · 1 line
2.13.7
#1 lore raw
Quoted 20 lines · David Disseldorp

Data-Out timeouts resulting in connection outages should be logged as errors.

---
 drivers/target/iscsi/iscsi_target_erl1.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/target/iscsi/iscsi_target_erl1.c +1 -2
index 5efa42b939a1..d75cc11ca83c 100644
@@ -1169,13 +1169,13 @@ void iscsit_handle_dataout_timeout(struct timer_list *t)
 	na = iscsit_tpg_get_node_attrib(sess);
 
 	if (!sess->sess_ops->ErrorRecoveryLevel) {
-		pr_debug("Unable to recover from DataOut timeout while"
-			" in ERL=0.\n");
+		pr_err("Unable to recover from DataOut timeout while"

drivers/target/iscsi/iscsi_target_erl1.c void iscsit_handle_dataout_timeout(struct timer_list *t) · line 1181

Quoted 10 lines
drivers/target/iscsi/iscsi_target_erl1.c +2 -1
+			" in ERL=0, closing iSCSI connection.\n");
 		goto failure;
 	}
 
 	if (++cmd->dataout_timeout_retries = na->dataout_timeout_retries) {
-		pr_debug("Command ITT: 0x%08x exceeded max retries"
+		pr_err("Command ITT: 0x%08x exceeded max retries"
 			" for DataOUT timeout %u, closing iSCSI connection.\n",
 			cmd->init_task_tag, na->dataout_timeout_retries);
 		goto failure;

For this and the nop one I think we should print something so we know what session failed. For the nop one the sid can change on relogin if this was the only session, so you can't later match it from the logs and configfs.

Maybe in the nop/dataout failure path add the I_T nexus values for the failed session in the failure message or maybe for both messages log the {sid, cid} but then on login also log a message indicating a connection logged in and the I_T nexus to sid/cid mapping.

#2 lore raw
In reply to David Disseldorp
Quoted 24 lines · Mike Christie
Quoted 23 lines · David Disseldorp

Data-Out timeouts resulting in connection outages should be logged as errors.

---
 drivers/target/iscsi/iscsi_target_erl1.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/target/iscsi/iscsi_target_erl1.c +2 -2
index 5efa42b939a1..d75cc11ca83c 100644
@@ -1169,13 +1169,13 @@ void iscsit_handle_dataout_timeout(struct timer_list *t)
 	na = iscsit_tpg_get_node_attrib(sess);
 
 	if (!sess->sess_ops->ErrorRecoveryLevel) {
-		pr_debug("Unable to recover from DataOut timeout while"
-			" in ERL=0.\n");
+		pr_err("Unable to recover from DataOut timeout while"
+			" in ERL=0, closing iSCSI connection.\n");
 		goto failure;
 	}
 
Quoted 11 lines

drivers/target/iscsi/iscsi_target_erl1.c void iscsit_handle_dataout_timeout(struct timer_list *t) · line 1181

Quoted 7 lines
drivers/target/iscsi/iscsi_target_erl1.c +1 -1
 	if (++cmd->dataout_timeout_retries = na->dataout_timeout_retries) {
-		pr_debug("Command ITT: 0x%08x exceeded max retries"
+		pr_err("Command ITT: 0x%08x exceeded max retries"
 			" for DataOUT timeout %u, closing iSCSI connection.\n",
 			cmd->init_task_tag, na->dataout_timeout_retries);
 		goto failure;

For this and the nop one I think we should print something so we know what session failed. For the nop one the sid can change on relogin if this was the only session, so you can't later match it from the logs and

I meant only connection in the session.

Quoted 8 lines

configfs.

Maybe in the nop/dataout failure path add the I_T nexus values for the failed session in the failure message or maybe for both messages log the {sid, cid} but then on login also log a message indicating a connection logged in and the I_T nexus to sid/cid mapping.